Use of Subharmonics of Base Frequencies in the CSRMT Method with Loop Sources

Author:

Saraev Alexander K.1ORCID,Bobrov Nikita Yu.1ORCID,Shlykov Arseny A.1

Affiliation:

1. Institute of Earth Sciences, St. Petersburg State University, 199034 St. Petersburg, Russia

Abstract

In the controlled source radiomagnetotelluric (CSRMT) sounding method, a horizontal magnetic dipole, HMD (vertical loop) or a horizontal electric dipole, and HED (grounded line) are used as sources. When working with HMD, the source is usually tuned to resonance to increase the current in the loop. However, the disadvantage of this approach is the narrow frequency range realized in the CSRMT method (1–12 kHz) and the short operating distance from the source (600–800 m). The need to tune the source to resonance at each selected frequency reduces the efficiency of the survey. In the case of using HED for sounding, measurements are performed in a wider frequency range of 1 to 1000 kHz, and along with the signal of the base frequency, its subharmonics are measured. In this case, emitted signal measurements are possible at a distance of up to 3–4 km from the source. At the same time, the disadvantage of using HED is that it requires grounding, the arrangement of which requires additional time when working on frozen ground or dry stony soil. We consider the possibilities of generation and registration of signals of subharmonics of base frequencies when applying the CSRMT method with loop sources—HMD and VMD (horizontal loop). A matching unit (MU) based on a step-up transformer was developed, which increases the output voltage of the CSRMT transmitter. In a field test with base frequencies of 20, 40, and 80 kHz, the signal amplitudes increased by a factor of two to four for subharmonics at frequencies of 60–200 kHz and by up to 10–13 times for subharmonics at frequencies of 200–500 kHz due to transformation of signal spectrum provided by MU. The possibility of using odd subharmonics of base frequencies for inversion has been demonstrated in the results of field experiments with different sources (HED, HMD, and VMD). This expands the frequency range of the method when working with loop sources and increases the survey’s effectiveness. The use of loop sources in the CSRMT method is especially advantageous for winter work in Arctic regions.

Funder

Russian Science Foundation

Publisher

MDPI AG

Subject

Psychiatry and Mental health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3