Abstract
In order to solve the problem of uneven air inlet flow in the guide channel of autoclave, three optimization schemes for the guide plate were proposed. The flow field in the guide channels of autoclave was simulated and analyzed by the realizable k-epsilon turbulence model and dynamic boundary method. The results show that the three optimization schemes have a certain effect on solving the problem of uneven air inlet flow in each guide channel, but some of them also have some negative effects. The integration of the three optimization schemes effectively increases the total air inlet flow of the guide channels; the increase ratio reaches 4.15%, improves the flow-field characteristics at the outlet of the guide channels and greatly reduces the difference in the air inlet flow in the left and right guide channels; the difference ratio drops from 62.61% to 5.37%.
Funder
National Natural Science Foundation of China
the Science and Technology Research Key Projects of Hebei Provincial Institution of Higher Ed-ucation
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献