An International Non-Inferiority Study for the Benchmarking of AI for Routine Radiology Cases: Chest X-ray, Fluorography and Mammography

Author:

Arzamasov Kirill1ORCID,Vasilev Yuriy12,Vladzymyrskyy Anton13,Omelyanskaya Olga1,Shulkin Igor1,Kozikhina Darya1,Goncharova Inna1,Gelezhe Pavel1,Kirpichev Yury1,Bobrovskaya Tatiana1,Andreychenko Anna1

Affiliation:

1. State Budget-Funded Health Care Institution of the City of Moscow “Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Health Care Department”, Petrovka Street, 24, Building 1, 127051 Moscow, Russia

2. Federal State Budgetary Institution “National Medical and Surgical Center Named after N.I. Pirogov” of the Ministry of Health of the Russian Federation, Nizhnyaya Pervomayskaya Street, 70, 105203 Moscow, Russia

3. Department of Information and Internet Technologies, I.M. Sechenov First Moscow State Medical University of the Ministry of Health of the Russian Federation (Sechenov University), Trubetskaya Street, 8, Building 2, 119991 Moscow, Russia

Abstract

An international reader study was conducted to gauge an average diagnostic accuracy of radiologists interpreting chest X-ray images, including those from fluorography and mammography, and establish requirements for stand-alone radiological artificial intelligence (AI) models. The retrospective studies in the datasets were labelled as containing or not containing target pathological findings based on a consensus of two experienced radiologists, and the results of a laboratory test and follow-up examination, where applicable. A total of 204 radiologists from 11 countries with various experience performed an assessment of the dataset with a 5-point Likert scale via a web platform. Eight commercial radiological AI models analyzed the same dataset. The AI AUROC was 0.87 (95% CI:0.83–0.9) versus 0.96 (95% CI 0.94–0.97) for radiologists. The sensitivity and specificity of AI versus radiologists were 0.71 (95% CI 0.64–0.78) versus 0.91 (95% CI 0.86–0.95) and 0.93 (95% CI 0.89–0.96) versus 0.9 (95% CI 0.85–0.94) for AI. The overall diagnostic accuracy of radiologists was superior to AI for chest X-ray and mammography. However, the accuracy of AI was noninferior to the least experienced radiologists for mammography and fluorography, and to all radiologists for chest X-ray. Therefore, an AI-based first reading could be recommended to reduce the workload burden of radiologists for the most common radiological studies such as chest X-ray and mammography.

Funder

USIS

Publisher

MDPI AG

Subject

Health Information Management,Health Informatics,Health Policy,Leadership and Management

Reference45 articles.

1. Reproducible Machine Learning Methods for Lung Cancer Detection Using Computed Tomography Images: Algorithm Development and Validation;Yu;J. Med. Internet Res.,2020

2. Trends in the on-call workload of radiologists;Herron;Clin. Radiol.,2006

3. Projection X-ray Imaging: Radiography, Mammography, Fluoroscopy;Seibert;Health Phys.,2019

4. Evaluation of Combined Artificial Intelligence and Radiologist Assessment to Interpret Screening Mammograms;Schaffter;JAMA Netw. Open,2020

5. (2021, July 22). Available online: https://apps.who.int/iris/bitstream/handle/10665/330829/9789289054782-eng.pdf.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献