Techno-Economic Design of Flue Gas Condensers for Medium-Scale Biomass Combustion Plants: Impact of Heat Demand and Return Temperature Variations

Author:

Coppieters Thibault,Blondeau Julien

Abstract

Despite their obvious benefit in terms of energy efficiency and their potential benefit on pollutant emissions, Flue Gas Condensers (FGCs) are still not widely spread in biomass combustion plants. Although their costs have significantly decreased during the last decade, the economic viability of FGC retrofits is not straightforward and their return on investments is mainly dependent on the temperature of the available heat sink and the moisture content of the fuel. Based on a new techno-economic model of a FGC validated with recent industrial data, this paper presents a methodology to assess the economic viability of an FGC retrofitting in a medium-scale biomass combustion plant. The proposed methodology is applied to the case of a typical District Heating plant for which real data was collected. For the first time, the usual assumptions of constant process data generally used are challenged by considering the variability of the return temperature and heat demand over the year. Furthermore, a new concept of optimal configurations in terms of energy savings is introduced in this paper and compared to a strictly economic optimum. The economic feasibility is mainly evaluated by means of the Net Present Value (NPV), Discounted Payback Period (DPP), and the Modified Internal Rate of Return (MIRR). As expected, results show that the higher the humidity level and the lower the return temperature, the higher the economic profitability of a project. The NPV is, however, increased when considering variable inputs: Even with an average return temperature of 60 °C, a mixed operation of the FGC as a condenser and an economizer along the year is predicted, which results in an increased profitability assessment. Considering a constant return temperature over the year can lead to a 20% underestimation of the project NPV. An alternative averaging method is proposed, where two distinct temperature zones are considered: above and below the flue gas dew point. The discrepancy with a detailed temperature variation is reduced to a few percents. Our results also show that increasing the FGC surface beyond the highest NPV can lead to substantial energy savings at a reasonable cost, up to a certain level. The energetic optimum we defined can lead to an increase in energy savings by 17% for the same relative decrease of the NPV.

Publisher

MDPI AG

Subject

Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3