Design of a Shock-Protected Structure for MEMS Gyroscopes over a Full Temperature Range

Author:

Xu Yingyu12ORCID,Lin Jing3,He Chunhua1ORCID,Wu Heng1,Huang Qinwen2,Yan Guizhen4

Affiliation:

1. School of Computer, Guangdong University of Technology, Guangzhou 510006, China

2. Science and Technology on Reliability Physics and Application Technology of Electronic Component Laboratory, China Electronic Product Reliability and Environmental Testing Research Institute, Guangzhou 510006, China

3. Classroom Management Center, Guangdong University of Technology, Guangzhou 510006, China

4. National Key Laboratory of Science and Technology on Micro/Nano Fabrication, Institute of Microelectronics, Peking University, Beijing 100871, China

Abstract

Impact is the most important factor affecting the reliability of Micro-Electro-Mechanical System (MEMS) gyroscopes, therefore corresponding reliability design is very essential. This paper proposes a shock-protected structure (SPS) capable of withstanding a full temperature range from −40 °C to 80 °C to enhance the shock resistance of MEMS gyroscopes. Firstly, the shock transfer functions of the gyroscope and the SPS are derived using Single Degree-of-Freedom and Two Degree-of-Freedom models. The U-folded beam stiffness and maximum positive stress are deduced to evaluate the shock resistance of the silicon beam. Subsequently, the frequency responses of acceleration of the gyroscope and the SPS are simulated and analyzed in Matlab utilizing the theoretical models. Simulation results demonstrate that when the first-order natural frequency of the SPS is approximately one-fourth of the gyroscope’s resonant frequency, the impact protection effect is best, and the SPS does not affect the original performance of the gyroscope. The acceleration peak of the MEMS gyroscope is reduced by approximately 23.5 dB when equipped with the SPS in comparison to its counterpart without the SPS. The anti-shock capability of the gyroscope with the SPS is enhanced by approximately 13 times over the full-temperature range. After the shock tests under the worst case, the gyroscope without the SPS experiences a beam fracture failure, while the performance of the gyroscope with the SPS remains normal, validating the effectiveness of the SPS in improving the shock reliability of MEMS gyroscopes.

Funder

National Natural Science Foundation of China

Natural Science Foundation of Guangdong Province

Basic and Applied Basic Research Project of Guangzhou Basic Research Program

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Mechanical Engineering,Control and Systems Engineering

Reference30 articles.

1. Hartzell, A.L., Da Silva, M.G., and Shea, H.R. (2010). MEMS Reliability, Springer Science & Business Media.

2. MEMS Based Energy Harvesting for the Internet of Things: A Survey;Sun;Microsyst. Technol.,2018

3. Tilli, M., Paulasto-Krockel, M., Petzold, M., Theuss, H., Motooka, T., and Lindroos, V. (2020). Handbook of Silicon Based MEMS Materials and Technologies, Elsevier. [3rd ed.]. Micro and Nano Technologies.

4. Failure Mode Analysis of MEMS Suspended Inductors under Mechanical Shock;Li;Microelectron. Reliab.,2018

5. Lian, J., Li, J., and Xu, L. (2019). The Effect of Displacement Constraints on the Failure of MEMS Tuning Fork Gyroscopes under Shock Impact. Micromachines, 10.

同舟云学术