Abstract
The turbulent pulsating flow and heat transfer in straight and 90° curved square pipes are investigated in this study. Both experimental temperature field measurements at the cross-sections of the pipes and conjugate heat transfer (CHT) simulation were performed. The steady turbulent flow was investigated and compared to the pulsating flow under the same time-averaged Reynolds number. The time-averaged Reynolds number of the pulsating flow, as well as the steady flow, was approximately 60,000. The Womersley number of the pulsating flow was 43.1, corresponding to a 30 Hz pulsating frequency. Meanwhile, the Dean number in the curved pipe was approximately 31,000. The results showed that the local heat flux of the pulsating flow was greater than that of the steady flow when the location was closer to the upstream pulsation generator. However, the total heat flux of the pulsating flow was less than that of the steady flow. Moreover, the instantaneous velocity and temperature fields of the simulation were used to demonstrate the heat transfer mechanism of the pulsating flow. The behaviors, such as the obvious separation between the air and pipe wall, the low-temperature core impingement, and the reverse flow, suppress the heat transfer.