Reliability and Repeatability of Pressure Center Analysis with Low-Dye Taping Using Force Platform Podiatry Sensors in Feet with Excessive Pronation

Author:

Madruga-Armada ÓscarORCID,Becerro-de-Bengoa-Vallejo RicardoORCID,Losa-Iglesias Marta ElenaORCID,Calvo-Lobo CesarORCID,Rodriguez-Sanz DavidORCID,Martínez-Jiménez Eva MaríaORCID,Mazoteras-Pardo Victoria,San-Antolín Marta

Abstract

Background: The analysis of the center of pressure (COP) is a method used to assess the foot function, but its reliability and repeatability have not been evaluated. COP can be altered by diverse conditions, like an excessive foot pronation. Low-Dye taping is commonly used for the treatment of symptoms related to an excessive pronation. To date, no study has evaluated the effects of the Low-Dye taping on COP and the duration of its effects. Thus, the main purpose of this manuscript was to assess the reliability and repeatability of the percentage of center of pressure locus area (%CLA) in feet with an excessive pronation, and secondarily, to assess that the Low-Dye taping modifies the %CLA during the immediate 48 h. Methods: An observational study of the reliability and repeatability of the %CLA variable with the Low-Dye taping in feet with excessive pronation was carried out. We used the EPS-Platform to evaluate the results of the variable in 6 conditions in a first session to evaluate the reliability of the results. We compared the results of the first session with the results in a second session to evaluate the repeatability of the results. We also carried out an ANOVA test to evaluate the changes that the taping produced in the variable between without taping with the rest of the 6 conditions. Results: For the %CLA, we observed a reliability greater than 0.80, measured by the interclass ratio index, both in the first session before taping, and in the second session before taping, thus being a repeatability variable. In the following times, with taping, at 10 min with tape, at 20 min with tape, at 24 h with tape and at 48 h with tape; an interclass ratio coefficient (ICC) higher than 0.80 was again obtained, thus being a reliable variable in all measurements made. The Low-Dye taping did not change %CLA from the time the tape was put in until 48 h (p-value = 1.000). Conclusions: The %CLA variable, in feet with excessive pronation, proved to be a reliable variable in all the measurements obtained before putting on the tape and during the following 48 h with the tape, and a repeatable variable. The Low-Dye taping did not change the %CLA from the time the tape was put in until 48 h.

Publisher

MDPI AG

Subject

Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3