Affiliation:
1. Swiss Federal Institute of Metrology METAS, Lindenweg 50, 3003 Bern, Switzerland
2. Department of Electrical and Electronic Engineering, University of Cagliari, Via Marengo 2, 09123 Cagliari, Italy
Abstract
Modern power systems are rapidly transitioning towards a fully digital substation paradigm. Based on the IEC 61850, a common communication protocol between the different intelligent electronic devices (IEDs) promises a significant enhancement in terms of efficiency and interoperability. In this context, synchronization represents a crucial aspect as it allows us to rigorously compare measurements taken at the same time in different locations. In this paper, we consider a measurement chain for synchrophasor estimation based on digital inputs: an instrument transformer, a stand-alone merging unit (SAMU) and a phasor measurement unit (PMU). Both the SAMU and the PMU are equipped with independent synchronization sources. In case the SAMU loses its synchronization, the final measurement result would be considered invalid until a complete restoration of the SAMU synchronization status. In view of a longer continuity of operation, this paper proposes an alternative approach to evaluate the PMU Time Quality in real-time. This approach allows for continuing crucial monitoring and control operations, such as state estimation and fault detection, even in the presence of temporary loss of synchronization. A characterization, in both simulated and experimental conditions, proves the potential and reliability of the proposed approach. In the considered test case, the come-back within a sufficient time quality is correctly detected in less than 200 s, while waiting for the full restoration of the SAMU time reference would cost several minutes.
Subject
General Agricultural and Biological Sciences
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献