Radiation Dose Reduction in Different Digital Radiography Systems: Impact on Assessment of Defined Bony Structures in Bearded Dragons (Pogona vitticeps)

Author:

Steiner Natalie1ORCID,Ludewig Eberhard2,Tebrün Wiebke3ORCID,Pees Michael1ORCID

Affiliation:

1. Department of Small Mammal, Reptile and Avian Diseases, University of Veterinary Medicine, 30559 Hanover, Germany

2. Division of Diagnostic Imaging, Department of Small Animals and Horses, University of Veterinary Medicine, 1210 Vienna, Austria

3. Wimex Agrarprodukte Import and Export GmbH, 93128 Regenstauf, Germany

Abstract

Three different digital detector systems were used to study the effect of a defined radiation dose reduction on the image quality of digital radiographs in bearded dragons (Pogona vitticeps). A series of radiographs of seven bearded-dragon cadavers with a body mass ranging from 132 g to 499 g were taken in dorsoventral projection. The digital systems employed included two computed radiography systems (CR) (one system with a needle-based and one with a powdered-based scintillator) and one direct radiography system (DR). Three levels of the detector dose were selected: A standard dose (defined based on the recommended exposure value of the CRP, D/100%), a half dose (D/50%), and a quarter dose (D/25%). Four image criteria and one overall assessment were defined for each of four anatomic skeletal regions (femur, rib, vertebra, and phalanx) and evaluated blinded by four veterinarians using a predefined scoring system. The results were assessed for differences between reviewers (interobserver variability), radiography systems, and dosage settings (intersystem variability). The comparison of the ratings was based on visual grading characteristic (VGC) analysis. Dose reduction led to significantly lower scores in all criteria by every reviewer, indicating a linear impairment of image quality in different skeletal structures in bearded dragons. Scores did not differ significantly between the different systems used, indicating no advantage in using a computed or direct radiography system to evaluate skeletal structures in bearded dragons. The correlation was significant (p ≤ 0.05) for interobserver variability in 100% of the cases, with correlation coefficients between 0.50 and 0.59. While demonstrating the efficacy of the use of digital radiography in bearded dragons and the similar quality in using different computed or direct radiography systems, this study also highlights the importance of the appropriate level of detector dose and demonstrates the limits of post-processing algorithm to compensate for insufficient radiation doses in bearded dragons.

Publisher

MDPI AG

Subject

General Veterinary,Animal Science and Zoology

Reference31 articles.

1. Diagnostic imaging of reproductive tract disorders in reptiles;Gumpenberger;Vet. Clin. Exot. Anim. Pract.,2017

2. Advanced radiography and ultrasonography in reptiles;Schumacher;Semin. Avian Exot. Pet Med.,2001

3. Radiographic anatomy and barium sulfate contrast transit time of the gastrointestinal tract of bearded dragons (Pogona vitticeps);Grosset;Vet. Radiol. Ultrasound,2014

4. Anatomical, radiographical and computed tomographic study of the limbs skeleton of the Euphrates soft shell turtle (Rafetus euphraticus);Ahranjani;Vet. Res. Forum,2016

5. Development of a technique for contrast radiographic examination of the gastrointestinal tract in ball pythons (Python regius);Banzato;Am. J. Vet. Res.,2012

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3