Clinical Outcome of Carbon Fiber Reinforced Polyetheretherketone Plates in Patients with Proximal Humeral Fracture: One-Year Follow-Up

Author:

Ziegler Patrick1,Maier Sven2,Stuby Fabian3,Histing Tina2,Ihle Christoph2,Stöckle Ulrich4,Gühring Markus5

Affiliation:

1. Department of Trauma and Reconstructive Surgery, Klinik Gut, 7500 St. Moritz, Switzerland

2. Department of Trauma and Reconstructive Surgery, BG Unfallklinik Tuebingen, Eberhard Karls University Tuebingen, Schnarrenbergstrasse 95, 72076 Tuebingen, Germany

3. BG Trauma Center, Department for Traumatology, Orthopedics and Surgery, 82418 Murnau am Staffelsee, Germany

4. Center for Musculoskeletal Surgery, Charité University Medicine Berlin, 10117 Berlin, Germany

5. Kronprinzenbau Klinik, 72764 Reutlingen, Germany

Abstract

Background: Proximal humerus fractures are seen frequently, particularly in older patients. The development of new osteosynthesis materials is being driven by the high complication rates following surgical treatment of proximal humerus fractures. Plate osteosyntheses made of steel, titanium and, for several years now, carbon fiber-reinforced polyetheretherketone (CFR-PEEK) are used most frequently. Methods: A prospective, randomized study was conducted in order to evaluate whether there are differences in the functional postoperative outcome when comparing CFR-PEEK and titanium implants for surgical treatment of proximal humerus fractures. The primary outcome of shoulder functionality 1 year after surgery was measured with the DASH score, the Oxford Shoulder Score, and the Simple Shoulder Test. Results: Bony consolidation of the respective fracture was confirmed in all the patients included in the study within the scope of postoperative follow-up care. No significant differences in the DASH score, Oxford Shoulder Score, or Simple Shoulder Test were observed 1 year post-operatively when comparing the implant materials CFR-PEEK and titanium. Conclusions: There are no differences in terms of the functional outcome between CFR-PEEK plates and titanium implants 1 year after surgery. Studies on the long-term outcomes using CFR-PEEK plates in osteoporotic bone should be the subject of further research.

Funder

Arthrex

Publisher

MDPI AG

Subject

General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3