Author:
Zhang Guohe,Kuang Zejie,Wei Sufen,Huang Kai,Liang Feng,Yang Cheng-Fu
Abstract
Digital speckle correlation method is widely used in the areas of three-dimensional deformation and morphology measurement. It has the advantages of non-contact, high precision, and strong stability. However, it is very complex to be carried out with low speed software implementation. Here, an improved full pixel search algorithm based on the normalized cross correlation (NCC) method considering hardware implementation is proposed. According to the field programmable gate array (FPGA) simulation results, the speed of hardware design proposed in this paper is 2000 faster than that of software in single point matching, and 600 times faster than software in multi-point matching. The speed of the presented algorithm shows an increasing trend with the increase of the template size when performing multipoint matching.
Funder
National Natural Science Foundation of China
Subject
Electrical and Electronic Engineering,Computer Networks and Communications,Hardware and Architecture,Signal Processing,Control and Systems Engineering
Cited by
5 articles.