The Real Post-Operative Range of Motion Differs from the Virtual Pre-Operative Planned Range of Motion in Reverse Shoulder Arthroplasty

Author:

Berhouet Julien12ORCID,Samargandi Ramy13ORCID,Favard Luc1,Turbillon Céline1,Jacquot Adrien4,Gauci Marc-Olivier5ORCID

Affiliation:

1. CHRU Trousseau Service d’Orthopédie Traumatologie, Faculté de Médecine de Tours, Université de Tours, 1C Avenue de la République, 37170 Tours, France

2. Equipe Reconnaissance de Forme et Analyse de l’Image, Laboratoire d’Informatique Fondamentale et Appliquée de Tours EA6300, Ecole d’Ingénieurs Polytechnique Universitaire de Tours, Université de Tours, 64 Avenue Portalis, 37200 Tours, France

3. Department of Orthopedic Surgery, Faculty of Medicine, University of Jeddah, Jeddah 23218, Saudi Arabia

4. Centre for Chirurgie des Articulations et du Sport (ARTICS), 24 rue du XXIème Régiment d’Aviation, 54000 Nancy, France

5. Institut Locomoteur et du Sport, Hôpital Pasteur 2, 30 Voie Romaine, 06000 Nice, France

Abstract

Introduction: The purpose of this study was to analyze the real range of motion (RoM) measured in patients operated on for reverse shoulder arthroplasty (RSA) and compare it to the virtual RoM provided by the preoperative planning software. Hypothesis: There was a difference between virtual and real RoM, which can be explained by different factors, specifically the scapula-thoracic (ST) joint. Methods: Twenty patients with RSA were assessed at a minimum follow-up of 18 months. Passive RoM in forward elevation abduction, without and with manually locking the ST joint, and in external rotation with arm at side were recorded. The humerus, scapula, and implants were manually segmented on post-operative CTs. Post-operative bony structures were registered to preoperative bony elements. From this registration, a post-operative plan corresponding to the real post-operative implant positioning was generated and the corresponding virtual RoM analysis was recorded. On the post-operative anteroposterior X-rays and 2D-CT coronal planning view, the glenoid horizontal line angle (GH), the metaphyseal horizontal line angle (MH), and the gleno-metaphyseal angle (GMA) were measured to assess the extrinsic glenoid inclination, as well as the relative position of the humeral and glenoid components. Results: There were some significant differences between virtual and post-operative passive abduction and forward elevation, with (55° and 50°, p < 0.0001) or without ST joint participation (15° and 27°, p < 0.002). For external rotation with arm at side, there was no significant difference between planning (24° ± 26°) and post-operative clinical observation (19° ± 12°) (p = 0.38). For the angle measurements, the GMA was significantly higher (42.8° ± 15.2° vs. 29.1°± 18.2°, p < 0.0001), and the GH angle, significantly lower on the virtual planning (85.2° ± 8.8° vs. 99.5° ± 12.5°, p < 0.0001), while the MH was not different (p = 0.33). Conclusions: The virtual RoM given by the planning software used in this study differs from the real post-operative passive RoM, except for external rotation. This can be explained by the lack of ST joint and soft tissues simulation. However, in focusing on the virtual GH participation, the simulation looks informative. Some modifications between the glenoid and humerus starting positions before running the motion analysis could be provided for making it more realistic and predictive of the RSA functional results. Level of evidence: III.

Publisher

MDPI AG

Subject

Medicine (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3