Determination of the Attenuation Coefficients of Epoxy Resin with Carbopol Polymer as a Breast Phantom Material at Low Photon Energy Range

Author:

Marashdeh Mohammad1ORCID,Abdulkarim Muthanna2ORCID

Affiliation:

1. Department of Physics, College of Sciences, Imam Mohammad Ibn Saud Islamic University (IMSIU), P.O. Box 90950, Riyadh 11623, Saudi Arabia

2. Department of Pharmaceutical Sciences, College of Pharmacy, Alfaisal University, P.O. Box 50927, Riyadh 11533, Saudi Arabia

Abstract

Six different composites of epoxy resin and Carbopol 974p polymer were prepared based on Carbopol 974p polymer concentrations of 0%, 5%, 10%, 15%, 20%, and 25%. The linear and mass attenuation coefficients, Half Value Layer (HVL), and mean free path (MFP) of these composites were determined using single-beam photon transmission in the energy range between 16.65 keV and 25.21 keV. This was carried out by determining the attenuation of ka1 X-ray fluorescent (XRF) photons from niobium, molybdenum, palladium, silver, and tin targets. The results were compared with theoretical values of three types of breast material (Breast 1, Breast 2, Breast 3) and Perspex, which was calculated using a XCOM computer program. The results show that there were no significant differences in the attenuation coefficient values after the consequent Carbopol additions. Moreover, it was found that the mass attenuation coefficients of all tested composites were close to those of Perspex and the values for Breast 3. The HVL and MFP results showed that the E25 sample is closer to the results of the Perspex material with differences of (0.53–1.15%) and (0.51–1.20%), respectively. In addition, the densities of the fabricated samples were in the range of 1.102–1.170 g/cm3, which is in the range of human breast density. A computed tomography (CT) scanner was used to investigate the CT number values for the fabricated samples. The CT numbers of all samples were in the range of human breast tissue (24.53–40.28 HU). Based on these findings, the fabricated epoxy–Carbopol polymer is a good candidate for use as a breast phantom material.

Funder

Alfaisal University internal research grant

Publisher

MDPI AG

Subject

Polymers and Plastics,General Chemistry

Reference26 articles.

1. Shetty, M.K. (2014). Breast Cancer Screening and Diagnosis: A Synopsis, Springer.

2. A test object for assessing image quality in mammography;White;Brit. J. Radiol.,1980

3. Radiation dose to organs and tissues from mammography: Monte Carlo and phantom study;Sechopoulos;Radiology,2008

4. A tissue-equivalent phantom series for mammography dosimetry;Argo;J. Appl. Clin. Med. Phys,2004

5. A new mammography dosimetric phantom;Almeida;Radiat. Prot. Dosim.,2012

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3