Abstract
Applying a proton beam in radiotherapy enables precise irradiation of the tumor volume, but only for continuous assessment of changes in patient anatomy. Proton beam range uncertainties in the treatment process may originate not only from physical beam properties but also from patient-specific factors such as tumor shrinkage, edema formation and sinus filling, which are not incorporated in tumor volume safety margins. In this paper, we evaluated variations in dose distribution in proton therapy resulting from the differences observed in the control tomographic images and the dosimetric influence of applied adaptive treatment. The data from weekly computed tomography (CT) control scans of 21 patients, which serve as the basis for adaptive radiotherapy, were used for this study. Dosimetric analysis of adaptive proton therapy (APT) was performed on patients with head and neck (H&N) area tumors who were divided into two groups: patients with tumors in the sinus/nasal area and patients with tumors in the brain area. For this analysis, the reference treatment plans were forward-calculated using weekly control CT scans. A comparative evaluation of organ at risk (OAR) dose-volume histogram (DVH) parameters, as well as conformity and homogeneity indices, was conducted between the initial and recalculated dose distributions to assess the necessity of the adaptation process in terms of dosimetric parameters. Changes in PTV volume after replanning were observed in seventeen patient cases, showing a discrepancy of over 1 cm3 in ten cases. In these cases, tumor progression occurred in 30% of patients, while regression was observed in 70%. The statistical analysis indicates that the use of the adaptive planning procedure results in a statistically significant improvement in dose distribution, particularly in the PTV area. The findings led to the conclusion that the adaptive procedure provides significant advantages in terms of dose distribution within the treated volume. However, when considering the entire patient group, APT did not result in a statistically significant dose reduction in OARs (α = 0.05).
Funder
Polish Ministry of Education and Science
Reference23 articles.
1. Potential proton and photon dose degradation in advanced head and neck cancer patients by intratherapy changes;Jakobi;J. Appl. Clin. Med. Phys.,2017
2. Paganetti, H., Botas, P., Sharp, G.C., and Winey, B. (2021). Adaptive proton therapy. Phys. Med. Biol., 66.
3. Myths and realities of range uncertainty;Lomax;Br. J. Radiol.,2020
4. Large anatomical changes in head-and-neck cancers–A dosimetric comparison of online and offline adaptive proton therapy;Lalonde;Clin. Transl. Radiat. Oncol.,2023
5. The partial adaptation strategy for online-adaptive proton therapy: A proof of concept study in head and neck cancer patients;Gambetta;Med. Phys.,2024