Frequency Dependence of Receiving Sensitivity of Ultrasonic Transducers and Acoustic Emission Sensors

Author:

Ono KanjiORCID

Abstract

Receiving displacement sensitivities (Rx) of ultrasonic transducers and acoustic emission (AE) sensors are evaluated using sinewave packet excitation method and compared to the corresponding data from pulse excitation method with a particular emphasis on low frequency behavior below 20 kHz, down to 10 Hz. Both methods rely on the determination of transmitter displacement characteristics using a laser interferometric method. Results obtained by two calibration methods are in good agreement, with average spectral differences below 1 dB, indicating that the two calibration methods yield identical receiving sensitivities. At low test frequencies, effects of attenuation increase substantially due to increasing sensor impedance and Rx requires correction in order to evaluate the inherent sensitivity of a sensor, or open-circuit sensitivity. This can differ by more than 20 dB from results that used common preamplifiers with ~10 kΩ input impedance, leading to apparent velocity response below 100 kHz for typical AE sensors. Damped broadband sensors and ultrasonic transducers exhibit inherent velocity response (Type 1) below their main resonance frequency. In sensors with under-damped resonance, a steep sensitivity decrease occurs showing frequency dependence of f2~f5 (Type 2), while mass-loaded sensors exhibit flat displacement response (Type 0). Such behaviors originate from sensor characteristics that can best be described by the damped harmonic oscillator model. This model accounts for the three typical behaviors. At low frequencies, typically below 1 kHz, receiving sensitivity exhibits another Type 0 behavior of frequency independent Rx. Seven of 12 sensors showed this flat region, while three more appear to approach the Type 0 region. This appears to originate from the quasi-static piezoelectric response of a sensing element. In using impulse method, a minimum pulse duration is necessary to obtain spectral fidelity at low frequencies and an approximate rule is given. Various factors for sensitivity improvement are also discussed.

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3