Using an onboard kilovoltage imager to measure setup deviation in intensity-modulated radiation therapy for head-and-neck patients
Author:
Affiliation:
1. Department of Medical Physics; Memorial Sloan-Kettering Cancer Center; New York New York U.S.A.
2. Department of Radiation Oncology; Memorial Sloan-Kettering Cancer Center; New York New York U.S.A.
Publisher
Wiley
Subject
Radiology Nuclear Medicine and imaging,Instrumentation,Radiation
Reference12 articles.
1. The effect of setup uncertainty on normal tissue sparing with IMRT for head-and-neck cancer;Manning;Int J Radiat Oncol Biol Phys.,2001
2. Systematic setup errors for IMRT in the head and neck region: effect on dose distribution;Samuelsson;Radiother Oncol.,2003
3. Adequate margins for random setup uncertainties in head-and-neck IMRT;Astreinidou;Int J Radiat Oncol Biol Phys.,2005
4. Accuracy of field alignment in radiotherapy of head and neck cancer utilizing individualized face mask immobilization: a retrospective analysis of clinical practice;Hess;Radiother Oncol.,1995
5. Setup error in radiotherapy: on-line correction using electronic kilovoltage and megavoltage radiographs;Pisani;Int J Radiat Oncol Biol Phys.,2000
Cited by 21 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Image preprocessing to improve the accuracy and robustness of mutual-information-based automatic image registration in proton therapy;Physica Medica;2022-09
2. Accuracy and Precision of a Veterinary Neuronavigation System for Radiation Oncology Positioning;Journal of Veterinary Medicine;2018-02-13
3. Quantitative Evaluation of Patient Positioning Error Using CBCT 3D Gamma Density Analysis in Radiotherapy;Progress in Medical Physics;2017
4. Set-up errors in head and neck cancer patients treated with intensity modulated radiation therapy: Quantitative comparison between three-dimensional cone-beam CT and two-dimensional kilovoltage images;Physica Medica;2015-12
5. An assessment of the magnitude of intra-fraction movement of head-and-neck IMRT cases and its implication on the action-level of the imaging protocol;Radiotherapy and Oncology;2014-09