Affiliation:
1. School of Information Technology Deakin University Burwood VIC 3125 Australia
2. Aston Digital Futures Institute, College of Physical Sciences and Engineering Aston University Birmingham UK
3. Institute for Physical Activity and Nutrition (IPAN) Deakin University Burwood VIC 3125 Australia
Abstract
AbstractAimsHeart failure is a serious condition that often goes undiagnosed in primary care due to the lack of reliable diagnostic tools and the similarity of its symptoms with other diseases. Non‐invasive monitoring of heart rate variability (HRV), which reflects the activity of the autonomic nervous system, could offer a novel and accurate way to detect and manage heart failure patients. This study aimed to assess the feasibility of using machine learning techniques on HRV data as a non‐invasive biomarker to classify healthy adults and those with heart failure.Methods and resultsWe used digitized electrocardiogram recordings from 54 adults with normal sinus rhythm and 44 adults categorized into New York Heart Association classes 1, 2, and 3, suffering from congestive heart failure. All recordings were sourced from the PhysioNet database. Following data pre‐processing, we performed time‐domain HRV analysis on all individual recordings, including root mean square of the successive difference in adjacent RR interval (RRi) (RMSSD), the standard deviation of RRi (SDNN, the NN stands for natural or sinus intervals), the standard deviation of the successive differences between successive RRi (SDSD), the number or percentage of RRi longer than 50 ms (NN50 and pNN50), and the average value of RRi [mean RR interval (mRRi)]. In our experimental classification performance evaluation, on the computed HRV parameters, we optimized hyperparameters and performed five‐fold cross‐validation using four machine learning classification algorithms: support vector machine, k‐nearest neighbour (KNN), naïve Bayes, and decision tree (DT). We evaluated the prediction accuracy of these models using performance criteria, namely, precision, recall, specificity, F1 score, and overall accuracy. For added insight, we also presented receiver operating characteristic (ROC) plots and area under the ROC curve (AUC) values. The overall best performance accuracy of 77% was achieved when KNN and DT were trained on computed HRV parameters with a 5 min time window. KNN obtained an AUC of 0.77, while DT attained 0.78. Additionally, in the classification of severe congestive heart failure, KNN and DT had the best accuracy of 91%, with KNN achieving an AUC of 0.88 and DT obtaining 0.92.ConclusionsThe results show that HRV can accurately predict severe congestive heart failure. The findings of this study could inform the use of machine learning approaches on non‐invasive HRV, to screen congestive heart failure individuals in primary care.
Funder
National Heart Foundation of Australia
Subject
Cardiology and Cardiovascular Medicine
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献