Computed tomography dose index determination in dose modulation prospectively involving the third‐generation iterative reconstruction and noise index

Author:

Scott Alexander W.1ORCID,Alancherry Alok Shankar Pookotte1,Lee Christina1,Eastman Emi1,Zhou Yifang1

Affiliation:

1. Department of Imaging Cedars‐Sinai Medical Center Los Angeles California USA

Abstract

AbstractPurposeOptimizing CT protocols is challenging in the presence of automatic dose modulation because the CT dose index (CTDIvol) at different patient sizes is unknown to the operator. The task is more difficult when both the image quality index and iterative reconstruction prospectively affect the dose determination. It is of interest in practice to be informed of the CTDIvol during the protocol initialization and evaluation. It was our objective to obtain a predictive relationship between CTDIvol, the image quality index, and iterative reconstruction strength at various patient sizes.MethodsDose modulation data were collected on a GE Revolution 256‐slice scanner utilizing a Mercury phantom and selections of the noise index (NI) from 8 to 17, the third generation iterative reconstruction (ASIR‐V) from 0% to 80%, and phantom diameters from 16 to 36 cm. The fixed parameters were 120 kVp, a pitch of .984, and a collimation of 40 mm with a primary slice width of 2.5 mm. The CTDIvol per diameter was based on the average tube current over three adjacent slices (same or similar diameter) multiplied by a conversion factor between the average mA of the series and the reported CTDIvol. The relationship between CTDIvol, NI, and ASIR‐V for each diameter was fitted with a 2nd order polynomial of ASIR‐V multiplied by a power law of NI.ResultsThe ASIR‐V fit parameters versus diameter followed a Lorentz function while the NI exponent versus diameter followed an exponential growth function. The CTDIvol predictions were accurate within 15% compared to phantom results on a separate GE Revolution. For clinical relevance, the phantom diameter was converted to an abdomen or chest equivalent diameter and was well matched to patient data.ConclusionThe fitted relationship for CTDIvol. for given values of NI and ASIR‐V blending for a range of phantom sizes was a good match to phantom and patient data. The results can be of direct help for selecting adequate parameters in CT protocol development.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3