The effects of flattening filter‐free beams and aperture shape controller on the complexity of conventional large‐field treatment plans

Author:

Hui Cheukkai B.1,Pourmoghaddas Amir1,Mutaf Yildirim D.1

Affiliation:

1. Department of Radiation Oncology Kaiser Permanente Dublin California USA

Abstract

AbstractPurposeThe purpose of this study was to investigate the impact of using flattening filter‐free (FFF) beams and the aperture shape controller (ASC) on the complexity of conventional large‐field treatment plans.Methods and materialsA total of 24 head and neck (H&N) and 24 prostate with pelvic nodes treatment plans were used in this study. Each plan was reoptimized using the original clinical objectives with both flattened and FFF beams, as well as six different ASC settings. The dosimetric qualities of each plan cohort were evaluated using commonly used dose‐volume histogram values, and plan complexities were assessed through metrics including monitor unit (MU)/Dose, change in gantry speed, multileaf collimator (MLC) speed, the edge area ratio metric (EM), and the equivalent square length.ResultsNo significant differences in dosimetric qualities were found between plans with flattened and FFF beams. The ASC settings did not have significant effects on dosimetric qualities in the H&N plan cohort, but the “very high” ASC setting resulted in poorer dosimetric results for the prostate plans. Plans with FFF beams had significantly higher MU/Dose compared to plans with flattened beams. The use of flattening filter (FF) had significant effects on the change in gantry speed, with flattened beams producing plans that required higher change in gantry speed. However, the FF did not have significant effects on MLC speed, EM, or equivalent square length. In contrast, ASC settings had significant effects on these three metrics; increasing the ASC level resulted in plans with decreasing MLC speed, lower edge area ratio, and higher equivalent square length.ConclusionThis study demonstrated that using FFF beams with various ASC settings, except for the “very high” level, can produce plans with reduced complexities without compromising dosimetric qualities in conventional large‐field treatment plans.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3