The dosimetric impact of titanium implants in spinal SBRT using four commercial treatment planning algorithms

Author:

Liu Chieh‐Wen1,Cho Young‐Bin1,Magnelli Anthony1,Angelov Lilyana1,Balagamwala Ehsan H.1,Chao Samuel T.1,Xia Ping1

Affiliation:

1. Department of Radiation Oncology, Taussig Cancer Institute Cleveland Clinic Cleveland Ohio USA

Abstract

AbstractTo evaluate the dosimetric impact of titanium implants in spine SBRT using four dose calculation algorithms. Twenty patients with titanium implants in the spine treated with SBRT without density override (DO) were selected. The clinical plan for each patient was created in Pinnacle and subsequently imported into Eclipse (AAA and AcurosXB) and Raystation (CC) for dose evaluation with and without DO to the titanium implant. We renormalized all plans such that 90% of the tumor volume received the prescription dose and subsequently evaluated the following dose metrics: (1) the maximum dose to 0.03 cc (Dmax), dose to 99% (D99%) and 90% (D90%) of the tumor volume; (2) Dmax and volumetric metrics of the spinal cord. For the same algorithm, plans with and without DO had similar dose distributions. Differences in Dmax, D99% and D90% of the tumor were on average <2% with slightly larger variations up to 5.58% in Dmax using AcurosXB. Dmax of the spinal cord for plans calculated with DO increased but the differences were clinically insignificant for all algorithms (mean: 0.36% ± 0.7%). Comparing to the clinical plans, the relative differences for all algorithms had an average of 1.73% (−10.36%–13.21%) for the tumor metrics and −0.93% (−9.87%–10.95%) for Dmax of the spinal cord. A few cases with small tumor and spinal cord volumes, dose differences of >10% in both D99% and Dmax of the tumor, and Dmax of the spinal cord were observed. For all algorithms, the presence of titanium implants in the spine for most patients had minimal impact on dose distributions with and without DO. For the same plan calculated with different algorithms, larger differences in volumetric metrics of >10% could be observed, impacted by dose gradient at the plan normalization volume, tumor volumes, plan complexity, and partial voxel volume interpolation.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3