Dosimetrically motivated beam‐angle optimization for non‐coplanar arc radiotherapy with and without dynamic collimator rotation

Author:

Bertholet Jenny1,Zhu Chengchen1,Guyer Gian1,Mueller Silvan1,Volken Werner1,Mackeprang Paul‐Henry1,Loebner Hannes A.1,Stampanoni Marco F. M.2,Aebersold Daniel M.1,Fix Michael K.1,Manser Peter1

Affiliation:

1. Division of Medical Radiation Physics and Department of Radiation Oncology Inselspital Bern University Hospital and University of Bern Bern Switzerland

2. Institute for Biomedical Engineering, ETH Zürich and PSI Villigen Switzerland

Abstract

AbstractBackgroundNon‐coplanar techniques have shown to improve the achievable dose distribution compared to standard coplanar techniques for multiple treatment sites but finding optimal beam directions is challenging. Dynamic collimator trajectory radiotherapy (colli‐DTRT) is a new intensity modulated radiotherapy technique that uses non‐coplanar partial arcs and dynamic collimator rotation.PurposeTo solve the beam angle optimization (BAO) problem for colli‐DTRT and non‐coplanar VMAT (NC‐VMAT) by determining the table‐angle and the gantry‐angle ranges of the partial arcs through iterative 4π fluence map optimization (FMO) and beam direction elimination.MethodsBAO considers all available beam directions sampled on a gantry‐table map with the collimator angle aligned to the superior‐inferior axis (colli‐DTRT) or static (NC‐VMAT). First, FMO is performed, and beam directions are scored based on their contributions to the objective function. The map is thresholded to remove the least contributing beam directions, and arc candidates are formed by adjacent beam directions with the same table angle. Next, FMO and arc candidate trimming, based on objective function penalty score, is performed iteratively until a desired total gantry angle range is reached. Direct aperture optimization on the final set of colli‐DTRT or NC‐VMAT arcs generates deliverable plans. colli‐DTRT and NC‐VMAT plans were created for seven clinically‐motivated cases with targets in the head and neck (two cases), brain, esophagus, lung, breast, and prostate. colli‐DTRT and NC‐VMAT were compared to coplanar VMAT plans as well as to class‐solution non‐coplanar VMAT plans for the brain and head and neck cases. Dosimetric validation was performed for one colli‐DTRT (head and neck) and one NC‐VMAT (breast) plan using film measurements.ResultsTarget coverage and conformity was similar for all techniques. colli‐DTRT and NC‐VMAT plans had improved dosimetric performance compared to coplanar VMAT for all treatment sites except prostate where all techniques were equivalent. For the head and neck and brain cases, mean dose reduction—in percentage of the prescription dose—to parallel organs was on average 0.7% (colli‐DTRT), 0.8% (NC‐VMAT) and 0.4% (class‐solution) compared to VMAT. The reduction in D2% for the serial organs was on average 1.7% (colli‐DTRT), 2.0% (NC‐VMAT) and 0.9% (class‐solution). For the esophagus, lung, and breast cases, mean dose reduction to parallel organs was on average 0.2% (colli‐DTRT) and 0.3% (NC‐VMAT) compared to VMAT. The reduction in D2% for the serial organs was on average 1.3% (colli‐DTRT) and 0.9% (NC‐VMAT). Estimated delivery times for colli‐DTRT and NC‐VMAT were below 4 min for a full gantry angle range of 720°, including transitions between arcs, except for the brain case where multiple arcs covered the whole table angle range. These times are in the same order as the class‐solution for the head and neck and brain cases. Total optimization times were 25%–107% longer for colli‐DTRT, including BAO, compared to VMAT.ConclusionsWe successfully developed dosimetrically motivated BAO for colli‐DTRT and NC‐VMAT treatment planning. colli‐DTRT and NC‐VMAT are applicable to multiple treatment sites, including body sites, with beneficial or equivalent dosimetric performances compared to coplanar VMAT and reasonable delivery times.

Funder

Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung

Publisher

Wiley

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3