Application of stable consistency wavelength in optimizing gasoline RON near‐infrared analysis model transfer

Author:

Wang Hong‐hong1ORCID,Yuan Hui2,Hu Yun‐chao1,Xiong Zhi‐xin1,Liu Zhi‐jian1,Wang Ying1,Huang Hao‐ran1

Affiliation:

1. College of Light Industry and Food Nanjing Forestry University Nanjing China

2. State Key Laboratory of Catalytic Materials and Reaction Engineering Sinopec Research Institute of Petroleum Processing CO., LTD. Beijing China

Abstract

AbstractThe purpose of model transfer is to solve the problem that multivariate calibration models cannot be shared among different near‐infrared spectrometers. Taking gasoline as the research object, the transfer analysis of its octane number model was carried out. The gasoline samples collected by two near‐infrared spectrometers of the same type were used as the research object. The screening wavelengths with consistent and stable signals (SWCSS) combined with competitive adaptive reweighted sampling (CARS), uninformative variable elimination (UVE), and successive projections algorithm (SPA) were used to reduce the adverse effects of invalid wavelengths in the SWCSS method; therefore, the analysis ability of the master model to the slave samples was improved. Partial least squares regression (PLSR) models based on SWCSS‐UVE, SWCSS‐CARS, and SWCSS‐SPA algorithms were established, and comparison was made between their analytical capabilities for slave samples and those of SWCSS, direct standardization (DS) algorithm , piecewise direct standardization (PDS) algorithm, and slope/bias (S/B) algorithm. The results shown that the SWCSS‐UVE and SWCSS‐CARS methods can be used to establish models from the 231 and 6 wavelengths selected from the consistent wavelengths, respectively. The root mean square error of prediction (RMSEP) of the gasoline octane number (RON) content of the direct analysis of the spectrum measured by the slave machine was reduced from 5.7490 to 0.3226 and 0.3250, respectively, which was better than the single SWCSS and DS, PDS, and SWCSS‐SPA methods, and was close to the model transfer accuracy of the S/B algorithm. The transfer accuracy of SWCSS‐UVE and SWCSS‐CARS was not much different, but the wavelength variable involved in the model transfer of the latter was much smaller than that of the former, and the AIC value of SWCSS‐CARS was −59.59, which was much smaller than the akaike information criterion (AIC) value of SWCSS‐UVE 398.42.

Publisher

Wiley

Subject

Applied Mathematics,Analytical Chemistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3