AbstractHomicide, suicide, or accident – elemental intoxication may be a cause in each of these types of deaths. Inductively coupled plasma mass spectrometry (ICP‐MS) has emerged as the gold standard analytical method for toxic metal analysis in both clinical and forensic settings. An ICP‐MS method was developed using a modified acidic workup for the quantitative determination of arsenic, lead, and thallium. Method validation focused on the assessment of linearity, between‐ and within‐day precisions, limits of detection (LoD) and lower limits of quantification (LLoQ), and carryover. The method was applied to analysis of postmortem peripheral blood samples from 279 forensic cases for which orders for chemical–toxicological examination had been received from the public prosecutor's office. Using six‐point and one‐point calibrations (latter for rapid screening purposes), precisions and accuracies ranged from −4.8 to 5.8% and −6.4 to 7.5%. Analytical sensitivities for As, Pb, and Tl were 0.08, 0.18, and 0.01 μg/l (LoD) and 0.23, 0.66, and 0.03 μg/l (LLoQ), respectively. Observed postmortem peripheral blood concentrations were As, 1.31 ± 3.42 μg/L; Pb, 17.4 ± 13.1 μg/L; and Tl, 0.11 ± 0.07 μg/L (mean ± standard deviation [SD]). Elemental concentrations, determined in additional quality control samples, were in good agreement to those obtained with an external ICP‐MS method based on alkaline sample processing. The current method is practicable and compatible with an ICP‐MS system used for trace element analysis in an accredited medical laboratory. It allows for implementation of low‐threshold investigations when metal intoxications are suspected in forensic routine.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3