Physicochemical and biological characteristics of River Hindon at Galheta station from 2009 to 2020

Author:

Singh Bhanu Pratap1ORCID,Choudhury Moharana2ORCID,Gupta Piyush3ORCID,Chadha Utkarsh4ORCID,Zewude Dinaol5

Affiliation:

1. Department of Civil Engineering, Faculty of Engineering and Technology SRM Institute of Science and Technology, Delhi‐NCR Campus Ghaziabad Uttar Pradesh India

2. Environmental Research and Management Division Voice of Environment (VoE) Guwahati Assam India

3. Department of Chemistry, Faculty of Engineering and Technology SRM Institute of Science and Technology, Delhi‐NCR Campus Ghaziabad Uttar Pradesh India

4. Department of Materials Science and Engineering, Faculty of Applied Sciences and Engineering University of Toronto, St. George Campus Toronto Ontario Canada

5. Department of Biology, School of Applied Natural Sciences Adama Science and Technology University Adama Oromia Ethiopia

Abstract

AbstractThis study aimed to assess the physicochemical and biological attributes of water in the Hindon River, located in Northern India and traversing through the districts of Saharanpur, Muzaffarnagar, Meerut, Baghpat, Ghaziabad, and Gautam Buddha Nagar. The study specifically examined crucial parameters, including Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), Chemical Oxygen Demand (COD), Total Alkalinity (TA), Sulphate (SO42−), Total Dissolved Solids (TDS), and the biological parameter, that is, Total Coliform. Data for these characteristics of the Hindon River were collected and analyzed based on measurements obtained at the Galheta station in District Baghpat, from 2009 to 2020. The study revealed significant yearly fluctuations in water quality parameters. DO (0.15–9 mg/L) and Total Coliform (319.09 MPN/100 mL to 23 × 106 MPN/100 mL) levels represented the most significant variations, while BOD (30.65–81.54 mg/L) and COD (80.08–170 mg/L) values consistently exceeded acceptable thresholds. TA (151.883–444.86 mg/L) had persistently fallen short of minimum standards, whereas SO42− (24.756–77.441 mg/L) remained within permissible limits. TDS (619–924.16 mg/L) consistently adhered to water quality standards. The findings indicated that the Hindon River's water quality consistently fell into the categories D or E as per Bureau of Indian Standards (IS: 2296) and Class III or IV according to the UNECE (United Nations Economic Commission for Europe) standards and failed to meet the stipulated criteria outlined in BIS (IS: 2490) and had fallen short of the water quality standards established by the World Health Organization (WHO). A correlation coefficient matrix was generated to assess the relationships among the mentioned parameters. The research findings emphasize the need for continuous monitoring of Hindon River water to protect the health of aquatic ecosystems and human well‐being.

Publisher

Wiley

Subject

Management, Monitoring, Policy and Law,Public Health, Environmental and Occupational Health,Pollution,Waste Management and Disposal

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3