Portable Liquid Chromatography

Author:

Cortés‐Bautista Sergio,Campíns‐Falcó Pilar

Abstract

AbstractThe development of miniaturized systems has opened the possibility of the introduction of hand‐portableliquid chromatography(LC), but this kind of LC has evolved slowly although it has significant potential for solving analytical challenges in various applications in situ or at situ monitoring, due to their ability to perform measurements at the point of the potential analytical problem occurs. This article provides an overview of the current state of the art of portable LC technology and its context. The first LC reported as portable was the OB‐4 or Milichrom, developed by Baram et al. in 1983, but this system is far away from the contemporary idea of portability although served as a basis for the later developed portable LCs. It was not until 2015, after notable advancements in pumps, detectors, column technology, and batteries that a new wave of portable LCs surged. A timeline with relevant portable LC contributions is given and their main features are described in the article. The Axcend Focus was the first commercialized capillary/nano portable LC. Sharma et al. in 2015 proposed a number of requirements that an LC system must achieve to be considered as portable and Rahimi et al. in 2020 developed criteria to assess LC portability namedportaBle fiEld Testing sTandard framEwoRk(BETTER) criteria, which evaluates: the system cost, performance, robustness, operation time, portability, and weight. To date, portable LC systems meet some of the grade 2 and 3 criteria for almost all assessments. The grade 4 and 5 criteria are deemed a challenge to be met by next‐generation devices. The capabilities of different pumping systems have been tested in several studies being the most popular option the syringe pumps. Injectors have not presented a major obstacle when they come to adapting to portable equipment. The downscaling of LC has been closely related to the dimensions of the analytical column, particularly to its internal diameter, capillary packed and monolithic columns have been employed. On‐columnlight‐emitting diode(LED) detection configurations, which do not make use of flow cells eliminating the associated dead volumes were proposed. Electrochemical detectors were also used in portable LC. Almost all portable LCs are homemade and were not commercialized, for most of them only a single paper was published and the number of real applications is scarce. New knowledge is necessary for advancing in portable LC.

Publisher

Wiley

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3