Abstract

AbstractPreprocessing fMRI data requires striking a fine balance between conserving signals of interest and removing noise. Typical steps of preprocessing include motion correction, slice timing correction, spatial smoothing, and high‐pass filtering. However, these standard steps do not remove many sources of noise. Thus, noise‐reduction techniques, for example, CompCor, FIX, and ICA‐AROMA have been developed to further improve the ability to draw meaningful conclusions from the data. The ability of these techniques to minimize noise while conserving signals of interest has been tested almost exclusively in resting‐state fMRI and, only rarely, in task‐related fMRI. Application of noise‐reduction techniques to task‐related fMRI is particularly important given that such procedures have been shown to reduce false positive rates. Little remains known about the impact of these techniques on the retention of signal in tasks that may be associated with systemic physiological changes. In this paper, we compared two ICA‐based, that is FIX and ICA‐AROMA, two CompCor‐based noise‐reduction techniques, that is aCompCor, and tCompCor, and standard preprocessing using a large (n = 101) fMRI dataset including noxious heat and non‐noxious auditory stimulation. Results show that preprocessing using FIX performs optimally for data obtained using noxious heat, conserving more signals than CompCor‐based techniques and ICA‐AROMA, while removing only slightly less noise. Similarly, for data obtained during non‐noxious auditory stimulation, FIX noise‐reduction technique before analysis with a covariate of interest outperforms the other techniques. These results indicate that FIX might be the most appropriate technique to achieve the balance between conserving signals of interest and removing noise during task‐related fMRI.

Funder

National Institute of Neurological Disorders and Stroke

Publisher

Wiley

Subject

Neurology (clinical),Neurology,Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology,Anatomy

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Resting-state networks;Reference Module in Neuroscience and Biobehavioral Psychology;2024

2. Denoising task‐related fMRI: Balancing noise reduction against signal loss;Human Brain Mapping;2023-09-27

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3