Personalized alignment techniques better restore the native trochlear groove compared to systematic alignment techniques in total knee arthroplasty

Author:

Orsi Alexander D.1ORCID,Shatrov Jobe2,Plaskos Christopher1,Kreuzer Stefan3

Affiliation:

1. Corin USA Raynham Massachusetts USA

2. Sydney Orthopaedic Research Institute Sydney New South Wales Australia

3. Inov8 Orthopedics Houston Texas USA

Abstract

AbstractPurposeThe relationship between constitutional coronal alignment and implant positioning on trochlear groove restoration in total knee arthroplasty (TKA) is poorly understood. This study aimed to determine whether the choice of alignment philosophy significantly affects the restoration of the trochlea groove.MethodsSixty‐one imageless robotic TKAs performed by a single orthopaedic surgeon were retrospectively reviewed. In each case, the entire native trochlea was digitized to generate the native femoral anatomy, and implants were planned according to a functional alignment (FA) technique. Final implant position was recorded using the validated bone resection planes from the navigation system. Simulated femoral component positions were generated according to previously described alignment techniques: mechanical alignment (MA), gap balancing (GB), kinematic alignment (KA), restricted kinematic alignment (rKA) and restricted inverse kinematic alignment (riKA). Trochlear angle (TA), trochlear under/overstuffing and mediolateral sulcus offset were compared between the six simulated alignment techniques, as well as the final implanted technique. Further analyses investigated the effect of preoperative coronal alignment on trochlear position. Comparisons were assessed with an analysis of variance and Welch's t‐tests or Wilcoxon's rank‐sum tests with Bonferroni corrections.ResultsThe implanted and simulated techniques all resulted in greater TA valgus compared to the native groove (p < 0.001). The implanted technique, KA and rKA were closer to the native TA than GB, MA and riKA (p > 0.001). All alignment philosophies understuffed the native trochlea groove. KA and rKA understuffed less than all other techniques (p < 0.001), and GB understuffed more than all other techniques (p < 0.001). In extension, all techniques shifted the trochlear sulcus laterally, while in flexion, they medialized it. These effects were most prominent in GB and MA.ConclusionPersonalized alignment techniques such as KA and rKA, which consider variations in individual anatomy, best restore the native patellar groove compared to systematic alignment techniques when using a standardized femoral component.Level of EvidenceLevel III, retrospective review.

Publisher

Wiley

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3