Bilateral extended FDK: An improved weighting method for static CT imaging

Author:

Zha Keyang1,Zhao Qingxian1,Luo Shouhua1,Li Yunxiang2

Affiliation:

1. School of Biological Science & Medical Engineering Southeast University Nanjing China

2. Nanovision Technology (Beijing) Co.,Ltd. Beijing China

Abstract

AbstractBackgroundImproving imaging speed has always been the focus of research in CT technology, which is related to the radiation dose and imaging quality of moving organs, including heart and blood vessels. However, it is difficult to achieve further improvement by increasing the rotation speed of the gantry due to its structural strength limitation. Differing from the conventional CTs, the static CT employs dozens of ray sources to acquire projection data from different angular ranges, and each source only needs to be rotated in a small range to finish a full 360° scan, thus greatly increasing the scanning speed.PurposeAs sources of static CT need to be evenly distributed over 360°, the sources and detectors have to be arranged on two parallel rings independently. Such a geometry can be considered as a special case of CT systems with a significantly large cone angle, that is, a part of the detector is missing in the vicinity of the mid‐plane. Due to restriction of upper and lower bounds of the cone angle of the static CT, there are uneven projection data varying in each portion of the reconstruction volume, the conventional analytical or iterative reconstruction methods may introduce artifacts in the reconstructed outcomes.MethodsFollowing the weighting approach extended FDK (xFDK) by Grimmer et al., we propose an improved bilateral xFDK algorithm (bixFDK), which focuses on the reconstruction of the expanded volume. With the same philosophy as xFDK in terms of weighting function design, bixFDK takes the longitudinal offset of the detector with respect to the source into consideration, making our method applicable to a wide range of CT geometries, especially for the static CT. Based on the proposed bixFDK, a new iterative scheme bixFDK‐IR is also constructed to extend the applications to a wide range of scan protocols such as sparse‐view scan.ResultsThe proposed method has been validated with the simulated phantom data and the actual clinical data of the static CT, and demonstrates that it can ensure good image quality and enlarge the reconstruction volume in z‐direction of the static CT.ConclusionsThe bixFDK algorithm is an ideal reconstruction approach for static CT geometry, and the iterative scheme of bixFDK‐IR is applicable to a wide range of CT geometries and scan protocols, thus providing a wide range of application scenarios.

Funder

National Natural Science Foundation of China

Publisher

Wiley

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3