Discordance between aPTT and anti‐Xa in monitoring heparin anticoagulation in mechanical circulatory support

Author:

Li Song1ORCID,Li Ang2,Beckman Jennifer A.3,Kim Christopher3,Granich Marian A.3,Mondin John1,Sabath Daniel E.3,Garcia David A.3,Mahr Claudius1

Affiliation:

1. Medical City Healthcare Dallas TX USA

2. Division of Hematology & Oncology Baylor College of Medicine Houston TX USA

3. University of Washington Seattle WA USA

Abstract

AbstractAimsIt is unclear whether activated partial thromboplastin time (aPTT) or anti‐Xa is more accurate for monitoring heparin anticoagulation in mechanical circulatory support (MCS) patients. This study investigates the relationship between aPTT and anti‐Xa in MCS patients and identifies predictors of discordance.Methods and resultsaPTT and anti‐Xa were simultaneously measured in a prospective cohort of MCS patients receiving unfractionated heparin at a tertiary academic medical centre. Therapeutic aPTT and anti‐Xa levels were 60–100 s and 0.3–0.7 IU/mL, respectively, and concordance was defined as both levels being subtherapeutic, therapeutic, or supratherapeutic. To identify predictors of discordance, both a machine learning random forest model and a multivariate regression model were applied to patient demographics, device type, and 14 laboratory variables; 23 001 pairs of simultaneously measured aPTT/anti‐Xa were collected from 699 MCS patients. aPTT and anti‐Xa were concordant in 35.5% of paired observations and discordant in 64.5% (aPTT > antiXa 61.5%; aPTT < antiXa 3.0%). Discordance with a high aPTT relative to anti‐Xa (aPTT > antiXa) was associated with high INR, eGFR, and total bilirubin, as well as low platelets, haemoglobin, pre‐albumin, white blood cell count, and haptoglobin. Total artificial heart and durable ventricular assist devices were more likely to be associated with aPTT > anti‐Xa than temporary MCS devices.ConclusionsaPTT and anti‐Xa were frequently discordant in MCS patients receiving heparin anticoagulation. Clinical conditions common in MCS patients such as concurrent warfarin use, malnutrition, haemolysis, and thrombocytopenia, as well as durable type of MCS devices were associated with a high aPTT relative to anti‐Xa.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3