Better resolving of anti‐CD38 antibody interference with blood compatibility testing by using manual polybrene method compared with dithiothreitol‐pretreatment indirect antiglobulin test

Author:

Feng Chiu‐Che12,Chang Ci‐Wen3,Lien Zhi‐Yi3,Lin Jinun‐An3,Chen Tzu‐Ting13,Yeh Su‐Peng145ORCID

Affiliation:

1. Division of Hematology and Oncology, Department of Internal Medicine China Medical University Hospital Taichung Taiwan

2. Graduate Institute of Medicine Kaohsiung Medical University Kaohsiung Taiwan

3. Blood Bank, Department of Laboratory Medicine China Medical University Hospital Taichung Taiwan

4. Transfusion Committee China Medical University Hospital Taichung Taiwan

5. College of Medicine China Medical University Taichung Taiwan

Abstract

AbstractBackgroundIt is advised to pretreat the reagent erythrocytes with Dithiothreitol (DTT) to denature the surface CD38 to prevent anti‐CD38 monoclonal antibodies (MoAb) from interfering with the blood compatibility test. Anti‐CD38 has little impact on the Polybrene test, but it is still unknown how sensitive it is to detect irregular antibodies and how effective it is when compared to the standard DTT‐based method.MethodsTwenty‐one patients receiving daratumumab (N = 13) and isatuximab (N = 8) had their serum collected. Standard anti‐sera (anti‐c, D, E, Fyb, Jka, M, Mia) with serial dilution were added to patients' serum. Antibody screening tests were performed simultaneously using the manual polybrene method (MP) and DTT‐pretreated, automatic indirect antiglobulin test (DTT‐IAT) to compare the detection sensitivity. These two methods' operating times and costs were also analyzed.ResultsBoth MP and DTT‐IAT can overcome the interference caused by anti‐CD38 MoAb. However, MP is more sensitive in detecting anti‐M and anti‐Mia and is comparable to DTT‐IAT in detecting other antibodies. In terms of cost and operating time, MP is also far superior to DTT‐IAT.ConclusionMP is a cost‐effective alternative to DTT‐IAT in resolving anti‐CD38 interference and is especially suitable for populations with a high prevalence of anti‐M and anti‐Mia. However, both methods have a well‐known drawback of low detection sensitivity for anti‐K, and K‐units should be provided to patients to prevent hemolytic transfusion reactions.

Publisher

Wiley

Subject

Microbiology (medical),Biochemistry (medical),Medical Laboratory Technology,Clinical Biochemistry,Public Health, Environmental and Occupational Health,Hematology,Immunology and Allergy

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3