Design and Implementation of a Wearable System Based on a Flexible Capacitive Sensor, Monitoring Knee Laxity

Author:

Sheeja Prakash Karthika1ORCID,Andersen Erik2,von Einem Vicky Chantal1,Muthalagu Sabari Kannan1,Agarwal Priyank1,Mayr Hermann Otto3,Seidenstuecker Michael3,Rosenstiel Nikolaus3,Roundy Shad2,Woias Peter1,Comella Laura Maria1

Affiliation:

1. Department of Microsystems Engineering – IMTEK University of Freiburg 79110 Freiburg im Breisgau Germany

2. Department of Mechanical Engineering University of Utah Salt Lake City 84112 USA

3. Department of Orthopedics and Trauma Surgery The University Medical Center Freiburg 79106 Freiburg im Breisgau Germany

Abstract

AbstractThe anterior cruciate ligament (ACL) tear is one of the most common knee injuries causing instability to the knee joint. Current methods of diagnosis fail to meet the ergonomic, reliability, and reproducibility requirements. Thus, the wearable sensors are gaining momentum to overcome current challenges. This paper aims at proposing a wearable capacitive based sensor system that shows a good potential in substituting the currently used methods for the diagnosis of ACL rupture. The developed sensor system measures the internal tibial rotation of the knee. It is compact and lightweight. Being cable free, it can be worn as a patch, without impeding the freedom of movement of the physician. Moreover, it can be powered with a battery or wireless. Both methods make it compact, ergonomic, easy for the patient to wear and for the doctor to use. To analyze the suitability of the developed sensing system, data from a knee simulator setup and three healthy volunteers (2 Males and 1 Female) are compared and analyzed. In all the patients, above 15° for every 5° angle variation, a relative change of capacitance with respect to its initial value of 0.01 is observed. These results are comparable with the knee simulator's data with a max RMSE of 0.002. Below 15° the system is additionally able to measure a gender‐based difference of rotation due to the higher flexibility of ligaments in females. For them the sensitivity below and above 15° is comparable, for male the sensitivity below 15° is lower. The results show that the developed system has good potential in substituting the currently used method for the diagnosis of ACL rupture and paves the way toward the continuous observation in free movement of knee laxity.

Publisher

Wiley

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3