Right parasternal echocardiographic reference values in the healthy male Iranian Shall sheep

Author:

Sadeghian Chaleshtori Sirous12ORCID,Mokber Dezfouli Mohammad Reza12,Vajhi Alireza23,Najd Ghahremani Abolfazl1ORCID,Sabetzadeh Neda2,Abbasi Javad4

Affiliation:

1. Department of Internal Medicine Faculty of Veterinary Medicine University of Tehran Tehran Iran

2. Institute of Biomedical Research University of Tehran Tehran Iran

3. Department of Surgery and Radiology Faculty of Veterinary Medicine University of Tehran Tehran Iran

4. Department of Animal and Poultry Health and Nutrition Faculty of Veterinary Medicine University of Tehran Tehran Iran

Abstract

AbstractBackgroundAmong the large animals, the heart of sheep is functionally and structurally very similar to the human heart. In research, sheep are used as an animal model to study the process of cardiac disease pathogenesis and treatment. Therefore, determining the normal values of the heart structures of sheep with echocardiography is of particular emphasis. The purpose of the present research is to define the normal echocardiography values of heart in Iranian Shall breed sheep.Materials and methodsIn 20 healthy Iranian Shall male sheep weighing 30–35 kg and aged 4–6 months, standing echocardiography was done from the right parasternal approach concentrated on the 3rd to 5th intercostal spaces by 2.5–5 MHz phased array transducer in the longitudinal and transverse views by B‐mode, M‐mode and Doppler systems. In M‐mode echocardiographic, the parameters of interventricular septal, left ventricular internal diameter, left ventricular free wall, right ventricular free wall and right ventricular internal diameter in diastole and systole as well as end point septal separation, ejection fraction (EF) slope, aortic root diameter, left atrial appendage, left atrial diameter/aortic valve diameter, left ventricular ejection time, fractional shortening, end‐diastolic volume, end‐systolic volume, EF, stroke volume and cardiac output and in pulsed‐wave spectral Doppler echocardiographic, the parameters of mitral valve maximum velocity (Vmax), mitral valve mean velocity (Vmean), mitral valve maximum pressure gradient (PGmax), mitral valve mean pressure gradient (PGmean), mitral valve velocity time integral (VTI), mitral valve E‐wave (MV‐E), MV‐E pressure gradient, mitral valve A‐wave (MV‐A), MV‐A pressure gradient, aortic Vmax, aortic valve Vmean, aortic valve PGmax, aortic valve PGmean, aortic valve VTI, left ventricular outflow tract (LVOT)‐Vmax, LVOT‐Vmean were measured.ResultsAll the sheep in this study were healthy and had no signs of heart disease. In this study, the parameters of M‐mode and spectral Doppler echocardiographic were assessed and recognized in Iranian Shall sheep. The results demonstrated the parameters of echocardiographic could be dependably determined in Shall sheep which, established normal reference values for these parameters and left ventricular function indices in healthy Shall sheep. These results can be beneficial in appropriate imagination, recognition and measuring cardiac structures.ConclusionThis study can be exerted as a reference for the assessment and diagnosis of heart diseases in sheep medicine and human cardiovascular research in sheep experimental models.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3