Additively manufactured Ti‐29Nb‐21Zr shows improved oxide polarization resistance versus Ti‐6Al‐4V in inflammatory simulating solution

Author:

Kurtz Michael A.12ORCID,Wessinger Audrey C.12,Mace Annsley12,Moreno‐Reyes Aldo12,Gilbert Jeremy L.12

Affiliation:

1. Department of Bioengineering Clemson University Clemson South Carolina USA

2. The Clemson University‐Medical University of South Carolina Bioengineering Program Charleston South Carolina USA

Abstract

AbstractRetrieval studies in the past two decades show severe corrosion of titanium and its alloys in orthopedic implants. This damage is promoted by mechanically assisted crevice corrosion (MACC), particularly within modular titanium‐titanium junctions. During MACC, titanium interfaces may be subject to negative potentials and reactive oxygen species (ROS), generated from cathodic activation and/or inflammation. Additive manufacturing (AM) may be able to produce new, corrosion‐resistant titanium alloys and admixtures that are less susceptible to these adverse electrochemical events. In this study, we characterize the impedance and corrosion properties of three new AM titanium materials, including Ti‐6Al‐4V with added 1% nano‐yttria stabilized ZrO2, admixed Ti‐29Nb‐21Zr, and pre‐alloyed Ti‐29Nb‐21Zr. We aim to elucidate how these materials perform when subjected to high ROS solutions. We include conventionally and additively manufactured Ti‐6Al‐4V in our study as comparison groups. A 0.1 M H2O2 phosphate‐buffered saline (PBS) solution, simulating inflammatory conditions, significantly increased biomaterial OCP (−0.14 V vs. Ag/AgCl) compared to PBS only (−0.38 V, p = .000). During anodic polarization, Ti‐6Al‐4V passive current density more than doubled from 1.28 × 10−7 to 3.81 × 10−7 A/cm2 when exposed to 0.1 M H2O2. In contrast, Ti‐29Nb‐21Zr passive current density remained relatively unchanged, slightly increasing from 7.49 × 10−8 in PBS to 9.31 × 10−8 in 0.1 M H2O2. Ti‐29Nb‐21Zr oxide polarization resistance (Rp) was not affected by 0.1 M H2O2, maintaining a high value (1.09 × 106 vs. 1.89 × 106 Ω cm2), while Ti‐6Al‐4V in 0.1 M H2O2 solution had significantly diminished Rp (4.38 × 106 in PBS vs. 7.24 × 104 Ω cm2 in H2O2). These results indicate that Ti‐29Nb‐21Zr has improved corrosion resistance in ROS containing solutions when compared with Ti‐6Al‐4V based biomaterials.

Funder

Wyss Foundation

Publisher

Wiley

Subject

Metals and Alloys,Biomedical Engineering,Biomaterials,Ceramics and Composites

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3