A simulation of a high‐resolution cadmium zinc telluride positron emission tomography system

Author:

Stanford‐Hill Riley1,Groll Andrew2,Levin Craig S.3

Affiliation:

1. Molecular Imaging Instrumentation Laboratory and Department of Physics Stanford University Stanford California USA

2. Molecular Imaging Instrumentation Laboratory and Department of Radiology Stanford University Stanford California USA

3. Department of Radiology (Molecular Imaging Program at Stanford/Nuclear Medicine) and, by Courtesy, of Physics, Electrical Engineering, and Bioengineering Stanford University Stanford California USA

Abstract

AbstractBackgroundA CZT (cadmium zinc telluride) PET (positron emission tomography) system is being developed at Stanford University. CZT has the promise of outperforming scintillator‐based systems in energy and spatial resolution but has relatively poor coincidence timing resolution.PurposeTo supplement GATE (GEANT 4 Application for Emission Tomography) simulations with charge transport and electronics modeling for a high‐resolution CZT PET system.MethodsA conventional GATE simulation was supplemented with electron‐hole transport modeling and experimentally measured single detector energy resolution to improve the system‐level understanding of a CZT high‐resolution PET system in development at Stanford University. The modeling used GATE hits data and applied charge transport in the crystal and RC‐CR processing of the simulated signals to model the electronics, including leading‐edge discriminators and peak pick‐off. Depth correction was also performed on the simulation data. Experimentally acquired data were used to determine energy resolution parameters and were compared to simulation data.ResultsThe distributions of the coincidence timing, anode energy, and cathode energy are consistent with experimental data. Numerically, the simulation achieved 153 ns FWHM coincidence time resolution (CTR), which is of the same order of magnitude as the raw 210 ns CTR previously found experimentally. Further, the anode energy resolution was found to be 5.9% FWHM (full width at half maximum) at 511 keV in the simulation, which is between the experimental value found for a single crystal of 3% and the value found for the dual‐panel setup of 8.02%, after depth correction.ConclusionsDeveloping this advanced simulation improves upon the limitations of GATE for modeling semiconductor PET systems and provides a means for deeper analysis of the coincidence timing resolution and other complementary electron‐hole dependent system parameters.

Funder

Stanford University

Publisher

Wiley

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3