An evaluation of isocentre shift magnitude and treatment site on image‐guided radiation therapy online decision analysis times

Author:

Clark Sarah1ORCID,Pollard Natalie1,Brown Elizabeth12ORCID

Affiliation:

1. Faculty of Health Queensland University of Technology Brisbane Queensland Australia

2. Radiation Oncology Princess Alexandra Hospital Brisbane Queensland Australia

Abstract

AbstractIntroductionThe ability to capture more anatomical detail in cone‐beam computed tomography (CBCT) imaging compared to kilovoltage (kV) and megavoltage (MV) imaging, has seen a documented shift towards CBCT image verification and staff adopting more extensive image analysis processes. The timeframe associated with assessing online CBCT images, termed the online decision analysis time, if drawn out, can affect treatment efficiency and accuracy. This study aimed to determine the current CBCT online decision analysis time at Radiation Oncology Princess Alexandra Ipswich Road (ROPAIR) and investigate the influence of isocentre shift magnitude and treatment site considerations on this timeframe.MethodsThis retrospective clinical audit collected treatment parameters from 202 CBCT images over 2 treatment days. The online decision analysis time was calculated by subtracting the image acquisition timestamp from the image verification shift application timestamp. The quantitative data were analysed using mean, standard deviation, and range in the following categories: all CBCTs, CBCTs grouped by isocentre shift magnitude and CBCTs grouped by treatment site. Content analysis was performed on staff comments made during image analysis.ResultsThe average online decision analysis time was 2:37 ± 1:28 min. On average approximately, head and neck, spine and extremity treatment sites measured 1 min, pelvis, breast, and chest measured 2–3 min with abdomen measuring 4 min. Common categories reported in staff comments included anatomical changes, repositioning, and organs at risk size.ConclusionThe results provide baseline online decision analysis times. Further refinement is required to determine if the image match method, treatment site considerations, and rotational discrepancies influence this timeframe.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Decision-making processes in image guided radiotherapy: A think aloud study;Journal of Medical Imaging and Radiation Sciences;2023-12

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3