Feasibility of high‐density electric source imaging in the presurgical workflow: Effect of number of spikes and automated spike detection

Author:

Heide Ev‐Christin1ORCID,van de Velden Daniel1ORCID,Garnica Agudelo David1ORCID,Hewitt Manuel1,Riedel Christian2,Focke Niels K.1ORCID

Affiliation:

1. Department of Neurology University Medical Center, Georg‐August University Göttingen Germany

2. Institute for Diagnostic and Interventional Neuroradiology University Medical Center, Georg‐August University Göttingen Germany

Abstract

AbstractObjectivePresurgical high‐density electric source imaging (hdESI) of interictal epileptic discharges (IEDs) is only used by few epilepsy centers. One obstacle is the time‐consuming workflow both for recording as well as for visual review. Therefore, we analyzed the effect of (a) an automated IED detection and (b) the number of IEDs on the accuracy of hdESI and time‐effectiveness.MethodsIn 22 patients with pharmacoresistant focal epilepsy receiving epilepsy surgery (Engel 1) we retrospectively detected IEDs both visually and semi‐automatically using the EEG analysis software Persyst in 256‐channel EEGs. The amount of IEDs, the Euclidean distance between hdESI maximum and resection zone, and the operator time were compared. Additionally, we evaluated the intra‐individual effect of IED quantity on the distance between hdESI maximum of all IEDs and hdESI maximum when only a reduced amount of IEDs were included.ResultsThere was no significant difference in the number of IEDs between visually versus semi‐automatically marked IEDs (74 ± 56 IEDs/patient vs 116 ± 115 IEDs/patient). The detection method of the IEDs had no significant effect on the mean distances between resection zone and hdESI maximum (visual: 26.07 ± 31.12 mm vs semi‐automated: 33.6 ± 34.75 mm). However, the mean time needed to review the full datasets semi‐automatically was shorter by 275 ± 46 min (305 ± 72 min vs 30 ± 26 min, P < 0.001).The distance between hdESI of the full versus reduced amount of IEDs of the same patient was smaller than 1 cm when at least a mean of 33 IEDs were analyzed. There was a significantly shorter intraindividual distance between resection zone and hdESI maximum when 30 IEDs were analyzed as compared to the analysis of only 10 IEDs (P < 0.001).SignificanceSemi‐automatized processing and limiting the amount of IEDs analyzed (~30–40 IEDs per cluster) appear to be time‐saving clinical tools to increase the practicability of hdESI in the presurgical work‐up.

Publisher

Wiley

Subject

Neurology (clinical),Neurology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3