Age, sex, and lung volume dependence of dissolved xenon‐129 MRI gas exchange metrics

Author:

Collier Guilhem J.12ORCID,Smith Laurie J.1,Saunders Laura C.1ORCID,Swift Andrew J.12,Marshall Helen12,Stewart Neil J.12ORCID,Norquay Graham1ORCID,Hughes Paul J. C.1ORCID,Thomspson A. A. Roger1ORCID,Wild Jim M.12

Affiliation:

1. POLARIS, Division of Clinical Medicine School of Medicine & Population Health, University of Sheffield Sheffield UK

2. Insigneo Institute, University of Sheffield Sheffield UK

Abstract

AbstractPurposeTo characterize the dependence of Xe‐MRI gas transfer metrics upon age, sex, and lung volume in a group of healthy volunteers.MethodsSixty‐five subjects with no history of chronic lung disease were assessed with 129Xe‐MRI using a four‐echo 3D radial spectroscopic imaging sequence and a dose of xenon titrated according to subject height that was inhaled from a lung volume of functional residual capacity (FRC). Imaging was repeated in 34 subjects at total lung capacity (TLC). Regional maps of the fractions of dissolved xenon in red blood cells (RBC), membrane (M), and airspace (Gas) were acquired at an isotropic resolution of 2 cm, from which global averages of the ratios RBC:M, RBC:Gas, and M:Gas were computed.ResultsData from 26 males and 36 females with a median age of 43 y (range: 20–69 y) were of sufficient quality to analyze. Age (p = 0.0006) and sex (p < 0.0001) were significant predictors for RBC:M, and a linear regression showed higher values and steeper decline in males: RBC:M(Males) = −0.00362 × Age + 0.60 (p = 0.01, R2 = 0.25); RBC:M(Females) = −0.00170 × Age + 0.44 (p = 0.02, R2 = 0.15). Similarly, age and sex were significant predictors for RBC:Gas but not for M:Gas. RBC:M, M:Gas and RBC:Gas were significantly lower at TLC than at FRC (plus inhaled volume), with an average 9%, 30% and 35% decrease, respectively.ConclusionExpected age and sex dependence of pulmonary function concurs with 129Xe RBC:M imaging results, demonstrating that these variables must be considered when reporting Xe‐MRI metrics. Xenon doses and breathing maneuvers should be controlled due to the strong dependence of Xe‐MRI metrics upon lung volume.

Funder

Engineering and Physical Sciences Research Council

National Institute for Health and Care Research

Medical Research Council

Publisher

Wiley

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3