Technical note: Determination of proton linear energy transfer from the integral depth dose

Author:

Yao Weiguang1,Farr Jonathan B.2,Mossahebi Sina1,Yi Byongyong1,Chen Shifeng1

Affiliation:

1. Department of Radiation Oncology University of Maryland School of Medicine Baltimore Maryland USA

2. Department of Medical Physics Applications of Detectors and Accelerators to Medicine Meyrin Switzerland

Abstract

AbstractBackgroundProton linear energy transfer (LET) is associated with the relative biological effectiveness of radiation on tissues. Monte Carlo (MC) simulations have been known to be the preferred method to calculate LET. Detectors have also been built to measure LET, but they need to be calibrated with MC simulations.PurposeTo propose and test a MC‐free method for determining LET from the measured integral depth dose (LFI) of the protons of interest.Method and materialsLFI consists of three steps: (1) IDD measurements, (2) extraction of energy spectrum (ES) from the IDD, and (3) LET determination from the extracted ES and the stopping power of each energy. To validate the accuracy of the extraction of ES, we use Gaussian ES to synthesize IDD, extract ES from the synthesized IDD, and then compare the original (ground truth) and extracted ES. LETs calculated from the original and extracted ES are also compared. To obtain the LET of protons of interest, we measure IDDs by a large‐area plane‐parallel ionization chamber in water. Finally, TOPAS MC is employed to simulate IDDs, ES, and LETs. From the simulated IDD, the extracted ES and LET are compared with the simulations from TOPAS MC.ResultsFrom the synthesized IDDs, the LETs agreed excellently when the peak energies ≥10 and 1.25 MeV with depth resolutions 0.1 and 0.01 mm, respectively. For energy <1.25 MeV, even higher depth resolution than 0.01 mm is required. From the MC simulated IDDs, our track‐averaged LET excellently agreed with MC simulation, but not the LETd. Our LETd was smaller than MC simulated LETd in the shallow region but larger in the distal Bragg peak region.ConclusionLET can be accurately determined from the IDD. This method can be used in the clinic to commission or validate LETs from other measurement methods or a treatment planning system.

Publisher

Wiley

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3