Three‐dimensional quantitative muscle ultrasound in patients with facioscapulohumeral dystrophy and myotonic dystrophy

Author:

de Jong Leon1ORCID,Greco Anna2,Nikolaev Anton1,Weijers Gert1,van Engelen Baziel G. M.2,de Korte Chris L.1,Fütterer Jurgen J.1

Affiliation:

1. Department of Medical Imaging Radboud University Medical Center, Radboud Institute for Health Sciences Nijmegen The Netherlands

2. Department of Neurology Radboud University Medical Center Nijmegen The Netherlands

Abstract

AbstractIntroduction/AimsUltrasound imaging of muscle tissue conventionally results in two‐dimensional sampling of tissue. For heterogeneously affected muscles, a sampling error using two‐dimensional (2D) ultrasound can therefore be expected. In this study, we aimed to quantify and extend ultrasound imaging findings in neuromuscular disorders by using three‐dimensional quantitative muscle ultrasound (3D QMUS).MethodsPatients with facioscapulohumeral dystrophy (n = 31) and myotonic dystrophy type 1 (n = 16) were included in this study. After physical examination, including Medical Research Council (MRC) scores, the tibialis anterior muscle was scanned with automated ultrasound. QMUS parameters were calculated over 15 cm of the length of the tibialis anterior muscle and were compared with a healthy reference data set.ResultsWith 3D QMUS local deviations from the healthy reference could be detected. Significant Pearson correlations (P < .01) between MRC score and QMUS parameters in male patients (n = 23) included the mean echo intensity (EI) (0.684), the standard deviation of EI (0.737), and the residual attenuation (0.841). In 91% of all patients, mean EI deviated by more than 1 standard deviation from the healthy reference. In general, the proportion of muscle tissue with a Z score >1 was about 50%.DiscussionIn addition to mean EI, multiple QMUS parameters reported in this study are potential biomarkers for pathology. Besides a moderate correlation of mean EI with muscle weakness, two other parameters showed strong correlations: standard deviation of EI and residual attenuation. Local detection of abnormalities makes 3D QMUS a promising method that can be used in research and potentially for clinical evaluation.

Publisher

Wiley

Subject

Physiology (medical),Cellular and Molecular Neuroscience,Neurology (clinical),Physiology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3