31P MR Spectroscopy in the Pancreas: Repeatability, Comparison With Liver, and Pilot Pancreatic Cancer Data

Author:

Seelen Leonard W.F.12ORCID,van den Wildenberg Lieke1,Gursan Ayhan1,Froeling Martijn1ORCID,Gosselink Mark W.J.M.1,van der Kemp Wybe J.M.1,Haj Mohammad Nadia3,Molenaar I. Quintus2,van Santvoort Hjalmar C.2,Klomp Dennis W.J.1,Prompers Jeanine J.1

Affiliation:

1. Center for Image Sciences University Medical Center Utrecht Utrecht The Netherlands

2. Department of Surgery UMC Utrecht Cancer Center and St Antonius Hospital Nieuwegein: Regional Academic Cancer Center Utrecht Utrecht The Netherlands

3. Department of Medical Oncology, UMC Utrecht Cancer Center Regional Academic Cancer Center Utrecht Utrecht The Netherlands

Abstract

BackgroundNon‐invasive evaluation of phosphomonoesters (PMEs) and phosphodiesters (PDEs) by 31‐phosphorus MR spectroscopy (31P MRS) may have potential for early therapy (non‐)response assessment in cancer. However, 31P MRS has not yet been applied to investigate the human pancreas in vivo.PurposeTo assess the technical feasibility and repeatability of 31P MR spectroscopic imaging (MRSI) of the pancreas, compare 31P metabolite levels between pancreas and liver, and determine the feasibility of 31P MRSI in pancreatic cancer.Study TypeProspective cohort study.Population10 healthy subjects (age 34 ± 12 years, four females) and one patient (73‐year‐old female) with pancreatic ductal adenocarcinoma.Field Strength/Sequence7‐T, 31P FID‐MRSI, 1H gradient‐echo MRI.Assessment31P FID‐MRSI of the abdomen (including the pancreas and liver) was performed with a nominal voxel size of 20 mm (isotropic). For repeatability measurements, healthy subjects were scanned twice on the same day. The patient was only scanned once. Test–retest 31P MRSI data of pancreas and liver voxels (segmented on 1H MRI) of healthy subjects were quantified by fitting in the time domain and signal amplitudes were normalized to γ‐adenosine triphosphate. In addition, the PME/PDE ratio was calculated. Metabolite levels were averaged over all voxels within the pancreas, right liver lobe and left liver lobe, respectively.Statistical TestsRepeatability of test–retest data from healthy pancreas was assessed by paired t‐tests, Bland–Altman analyses, and calculation of the intrasubject coefficients of variation (CoVs). Significant differences between healthy pancreas and right and left liver lobes were assessed with a two‐way analysis of variance (ANOVA) for repeated measures. A P‐value <0.05 was considered statistically significant.ResultsThe intrasubject CoVs for PME, PDE, and PME/PDE in healthy pancreas were below 20%. Furthermore, PME and PME/PDE were significantly higher in pancreas compared to liver. In the patient with pancreatic cancer, qualitatively, elevated relative PME signals were observed in comparison with healthy pancreas.Data ConclusionIn vivo 31P MRSI of the human healthy pancreas and in pancreatic cancer may be feasible at 7 T.Evidence Level3Technical EfficacyStage 2

Funder

European Commission

KWF Kankerbestrijding

St. Antonius Ziekenhuis

Publisher

Wiley

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3