Comparison of continuous 24‑hour and 14‑day ECG monitoring for the detection of cardiac arrhythmias in patients with ischemic stroke or syncope

Author:

Chen Wei‐Cheng1,Wu Yu‐Lin2ORCID,Hsu Yu‐Cheng1,Hsu Jen‐Te1ORCID,Tseng Hung‐Pin3,Chen Chao‐Chin1,Chiang Meng‐Hsiu1,Hsiao Ju‐Feng1,Chin See‐Khong1,Huang Ying‐Li1,Lei Meng‐Huan1

Affiliation:

1. Division of Cardiology, Department of Internal Medicine Lo‐Tung Poh‐Ai Hospital Luodong Taiwan

2. Post‐Baccalaureate Program in Nursing, College of Nursing Taipei Medical University Taipei Taiwan

3. Division of Neurology, Department of Internal Medicine Lo‐Tung Poh‐Ai Hospital Luodong Taiwan

Abstract

AbstractBackgroundPrevious studies show that using 12‐lead electrocardiogram (ECG) or 24‐h ECG monitor for the detection of cardiac arrhythmia events in patients with stroke or syncope is ineffective.HypothesisThe 14‐day continuous ECG patch has higher detection rates of arrhythmias compared with conventional 24‐h ECG monitoring in patients with ischemic stroke or syncope.MethodsThis cross‐sectional study of patients with newly diagnosed ischemic stroke or syncope received a 24‐h ECG monitoring and 14‐day continuous cardiac monitoring patch and the arrhythmia events were measured.ResultsThis study enrolled 83 patients with ischemic stroke or syncope. The detection rate of composite cardiac arrhythmias was significantly higher for the 14‐day ECG patch than 24‐h Holter monitor (69.9% vs. 21.7%, p = .006). In patients with ischemic stroke, the detection rates of cardiac arrhythmias were 63.4% for supraventricular tachycardia (SVT), 7% for ventricular tachycardia (VT), 5.6% for atrial fibrillation (AF), 4.2% for atrioventricular block (AVB), and 1.4% for pause by 14‐day ECG patch, respectively. The significant difference in arrhythmic detection rates were found for SVT (45.8%), AF (6%), pause (1.2%), AVB (2.4%), and VT (9.6%) by 14‐day ECG patch but not by 24‐h Holter monitor in patients with ischemic stroke or syncope.ConclusionsA 14‐day ECG patch can be used on patients with ischemic stroke or syncope for the early detection of AF or other cardiac arrhythmia events. The patch can be helpful for physicians in planning medical or mechanical interventions of patients with ischemic stroke and occult AF.

Publisher

Wiley

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3