Quantitative assessment of adaptive radiotherapy for prostate cancer using deep learning: Bladder dose as a decision criterion

Author:

Wan Luping123,Jiang Yin13,Zhu Xianggao2,Wu Hao2,Zhao Wei13

Affiliation:

1. School of Physics Beihang University Beijing China

2. Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing) Department of Radiation Oncology Peking University Cancer Hospital and Institute Beijing China

3. Zhongfa Aviation Institute Beihang University Hangzhou China

Abstract

AbstractBackgroundAdaptive radiotherapy (ART) can incorporate anatomical variations in a reoptimized treatment plan for fractionated radiotherapy. An automatic solution to objectively determine whether ART should be performed immediately after the daily image acquisition is highly desirable.PurposeWe investigate a quantitative criterion for whether ART should be performed in prostate cancer radiotherapy by synthesizing pseudo‐CT (sCT) images and evaluating dosimetric impact on treatment planning using deep learning approaches.Method and materialsPlanning CT (pCT) and daily cone‐beam CT (CBCT) data sets of 74 patients are used to train (60 patients) and evaluate (14 patients) a cycle adversarial generative network (CycleGAN) that performs the task of synthesizing high‐quality sCT from daily CBCT. Automatic delineation (AD) of the bladder is performed on the sCT using the U‐net. The combination of sCT and AD allows us to perform dose calculations based on the up‐to‐date bladder anatomy to determine whether the original treatment plan (ori‐plan) is still applicable. For positive cases that the patients’ anatomical changes and the associated dose calculations warrant re‐planning, we made rapid plan revisions (re‐plan) based on the ori‐plan.ResultsThe mean absolute error within the region‐of‐interests (i.e., body, bladder, fat, muscle) between the sCT and pCT are 41.2, 25.1, 26.5, and 29.0HU, respectively. Taking the calculated results of pCT doses as the standard, for PTV, the gamma passing rates of sCT doses at 1 mm/1%, 2 mm/2% are 87.92%, 98.78%, respectively. The Dice coefficients of the AD‐contours are 0.93 on pCT and 0.91 on sCT. According to the result of dose calculation, we found when the bladder volume underwent a substantial change (79.7%), the bladder dose is still within the safe limit, suggesting it is insufficient to solely use the bladder volume change as a criterion to determine whether adaptive treatment needs to be done. After AD‐contours of the bladder using sCT, there are two cases whose bladder dose . For the two cases, we perform re‐planning to reduce the bladder dose to , under the condition that the PTV meets the prescribed dose.ConclusionWe provide a dose accurate adaptive workflow for prostate cancer patients by using deep learning approaches, and implement ART that adapts to bladder dose. Of note, the specific replanning criterion for whether ART needs to be performed can adapt to different centers’ choices based on their experience and daily observations.

Funder

Natural Science Foundation of Zhejiang Province

National Natural Science Foundation of China

Fundamental Research Funds for the Central Universities

Publisher

Wiley

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3