A robust treatment planning approach for chest motion in postmastectomy chest wall intensity modulated radiation therapy

Author:

Miyasaka Yuya1,ono Takuya1,Chai Hongbo1,Souda Hikaru1,Lee Sung Hyun1,Ishizawa Miyu1,Akamatsu Hiroko2,Sato Hiraku2,Iwai Takeo1

Affiliation:

1. Department of Heavy Particle Medical Science Yamagata University Graduate School of Medical Science Yamagata Japan

2. Department of Radiology Yamagata University Faculty of Medicine Yamagata Japan

Abstract

AbstractPurposeChest wall postmastectomy radiation therapy (PMRT) should consider the effects of chest wall respiratory motion. The purpose of this study is to evaluate the effectiveness of robustness planning intensity modulated radiation therapy (IMRT) for respiratory movement, considering respiratory motion as a setup error.Material and methodsThis study analyzed 20 patients who underwent PMRT (10 left and 10 right chest walls). The following three treatment plans were created for each case and compared. The treatment plans are a planning target volume (PTV) plan (PP) that covers the PTV within the body contour with the prescribed dose, a virtual bolus plan (VP) that sets a virtual bolus in contact with the body surface and prescribing the dose that includes the PTV outside the body contour, and a robust plan (RP) that considers respiratory movement as a setup uncertainty and performs robust optimization. The isocenter was shifted to reproduce the chest wall motion pattern and the doses were recalculated for comparison for each treatment plan.ResultNo significant difference was found between the PP and the RP in terms of the tumor dose in the treatment plan. In contrast, VP had 3.5% higher PTV Dmax and 5.5% lower PTV V95% than RP (p < 0.001). The RP demonstrated significantly higher lung V20Gy and Dmean by 1.4% and 0.4 Gy, respectively, than the PP. The RP showed smaller changes in dose distribution affected by chest wall motion and significantly higher tumor dose coverage than the PP and VP.ConclusionWe revealed that the RP demonstrated comparable tumor doses to the PP in treatment planning and was robust for respiratory motion compared to both the PP and the VP. However, the organ at risk dose in the RP was slightly higher; therefore, its clinical use should be carefully considered.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3