Improved reproducibility for myocardial ASL: Impact of physiological and acquisition parameters

Author:

Božić‐Iven Maša12ORCID,Rapacchi Stanislas3ORCID,Tao Qian2ORCID,Pierce Iain4ORCID,Thornton George45ORCID,Nitsche Christian456ORCID,Treibel Thomas A.45ORCID,Schad Lothar R.1,Weingärtner Sebastian2ORCID

Affiliation:

1. Medical Faculty Mannheim Heidelberg University Mannheim Germany

2. Department of Imaging Physics Delft University of Technology Delft The Netherlands

3. CNRS, CRMBM Aix‐Marseille Université Marseille France

4. Barts Heart Centre St Bartholomew's Hospital London UK

5. Institute of Cardiovascular Science University College London London UK

6. Division of Cardiology Medical University of Vienna Vienna Austria

Abstract

AbstractPurposeTo investigate and mitigate the influence of physiological and acquisition‐related parameters on myocardial blood flow (MBF) measurements obtained with myocardial Arterial Spin Labeling (myoASL).MethodsA Flow‐sensitive Alternating Inversion Recovery (FAIR) myoASL sequence with bSSFP and spoiled GRE (spGRE) readout is investigated for MBF quantification. Bloch‐equation simulations and phantom experiments were performed to evaluate how variations in acquisition flip angle (FA), acquisition matrix size (AMS), heart rate (HR) and blood relaxation time () affect quantification of myoASL‐MBF. In vivo myoASL‐images were acquired in nine healthy subjects. A corrected MBF quantification approach was proposed based on subject‐specific values and, for spGRE imaging, subtracting an additional saturation‐prepared baseline from the original baseline signal.ResultsSimulated and phantom experiments showed a strong dependence on AMS and FA (>0.73), which was eliminated in simulations and alleviated in phantom experiments using the proposed saturation‐baseline correction in spGRE. Only a very mild HR dependence (>0.59) was observed which was reduced when calculating MBF with individual . For corrected spGRE, in vivo mean global spGRE‐MBF ranged from 0.54 to 2.59 mL/g/min and was in agreement with previously reported values. Compared to uncorrected spGRE, the intra‐subject variability within a measurement (0.60 mL/g/min), between measurements (0.45 mL/g/min), as well as the inter‐subject variability (1.29 mL/g/min) were improved by up to 40% and were comparable with conventional bSSFP.ConclusionOur results show that physiological and acquisition‐related factors can lead to spurious changes in myoASL‐MBF if not accounted for. Using individual and a saturation‐baseline can reduce these variations in spGRE and improve reproducibility of FAIR‐myoASL against acquisition parameters.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3