Assessment of scatter radiation dose received by comforters and carers during digital breast tomosynthesis mammography

Author:

Kostidis Michelle1ORCID,Varcoe Joshua GORCID,Barnes Peter1

Affiliation:

1. Austin Health, Repatriation Hospital Campus 300 Waterdale Road Heidelberg Heights Victoria Australia

Abstract

IntroductionMammographic imaging can cause considerable stress and anxiety for some patients and may require someone to remain in the room during the procedure to provide both physical and emotional support. As such, these comforters and carers (C&C) are exposed to ionising radiation. Limited evidence is available stating the radiation dose received during a digital breast tomosynthesis (DBT) examination. This research aims to determine the optimal standing position for a C&C in the mammography room during a DBT mammogram that results in the lowest radiation dose, whilst providing high‐quality imaging, care and comfort to the patient.MethodsA scatter detector was used to measure the dose at different standing positions of the carer relative to the patient during an examination. A polymethyl methacrylate (PMMA) phantom was also used to model the patient's breast and torso for further scatter dose measurements.ResultsThe median air kerma for craniocaudal views posterior to the patient is 0.75 μGy compared with 10.1 μGy to either side. The median air kerma for mediolateral oblique views for posterolateral position is 0.41 μGy compared with 2.6 μGy anterolateral. No significant effect from breast density is noted from the dataset.ConclusionThe optimal position for the C&C to stand is directly behind the patient in the craniocaudal position, and as far as possible posterolateral to the breast being imaged in the mediolateral oblique position. These two positions will result in the least radiation dose to the C&C.

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Reference20 articles.

1. Pilot trial of digital breast tomosynthesis (3D mammography) for population‐based screening in BreastScreen Victoria

2. 3D mammography: More breast cancers detected;Swannell C;Med J Aust,2019

3. Australian Radiation Protection and Nuclear Safety Agency (ARPANSA).Code for Radiation Protection in Medical Exposure. Radiation Protection Series C‐5 2019.

4. AG. Privacy Act1988. Available from:https://www.legislation.gov.au/Details/C2021C00139/Html/Text http://www.legislation.gov.au/Details/C2021C00139[Accessed 21 April 2022].

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3