Breast reconstruction using a superficial inferior epigastric artery flap with pedicle elongation via an arteriovenous loop: A case report

Author:

Otsuka Wataru1,Karakawa Ryo1ORCID,Yoshimatsu Hidehiko1ORCID,Yano Tomoyuki1ORCID

Affiliation:

1. Department of Plastic and Reconstructive Surgery Cancer Institute Hospital of the Japanese Foundation for Cancer Research Koto‐ku Tokyo Japan

Abstract

AbstractSuperficial inferior epigastric artery (SIEA) flap is often chosen to minimize postoperative complications such as abdominal pain and bulging. However, drawbacks, including a small diameter and a short pedicle, pose challenges in anastomosing or creating the lower pole of the breast. Here, we report a case of breast reconstruction using an SIEA flap with pedicle elongation via an arteriovenous loop (AV‐loop) using a contralateral superficial inferior epigastric vein (SIEV) graft. A 49‐year‐old woman underwent a left total mastectomy with the primary insertion of a tissue expander. Breast reconstruction using an SIEA flap with pedicle elongation was planned. The running pattern, pedicle length, and diameter of bilateral SIEA/SIEV and superficial circumflex iliac artery and vein (SCIA/SCIV) were evaluated preoperatively using a 48‐MHz probe of ultra‐high‐frequency ultrasonography (Vevo MD ultrasound device, Fujifilm Visual Sonics, Amsterdam, the Netherlands). During the flap harvesting, the contralateral SIEV graft was harvested to create an AV‐loop for pedicle elongation. The 9 cm graft was anastomosed to the left internal mammary artery and vein (IMA/IMV). After the flap elevation, the created AV‐loop was divided at the midpoint and anastomosed to the pedicle of the SIEA flap. The SIEA flap, extended with a SIEV AV‐loop, facilitated the augmentation of the lower pole of the breast without the risk of pedicle kinking and pulling. The postoperative course was uneventful, and the patient was discharged on postoperative day 7. The prolonged pedicle length via an AV‐loop prevents the pedicle kinking and allows for positioning the flap more freely, resulting in an aesthetically good breast contour by filling in the lower pole. The precise preoperative evaluation of the vessels using ultra‐high‐frequency ultrasonography facilitated meticulous planning. In cases where surgeons aim to minimize intraoperative and postoperative complications associated with other abdominal free flaps, this method may be considered a viable and promising option.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3