Affiliation:
1. Department of Chemistry GITAM School of Science (Deemed to be University) Hyderabad India
2. Department of Analytical Research and Development Amneal Pharmaceuticals Piscataway New Jersey USA
3. Department of Research and Development and Quality Operations InvaHealth Inc. Cranbury New Jersey USA
Abstract
AbstractA simple and robust high‐performance liquid chromatography (HPLC) method was developed for organic impurities of hydroxyzine hydrochloride in pharmaceuticals. The developed method was designed to estimate all organic impurities of hydroxyzine. The HPLC separation was achieved using C18 column (150 × 3.9 mm, 5 μm) along with a binary gradient consisting of mobile phases A (0.1%, trifluoroacetic acid in purified water) and B (0.05%, trifluoroacetic acid in acetonitrile), a flow rate of 0.7–mL/min, a column temperature of 30°C and a sample temperature of 25°C. The detection wavelength used was 230 nm for the estimation of impurity‐A, impurity‐B, and all unspecified impurities and degradation products, whereas impurity‐C was quantitated using 254 nm. The stability‐indicating property of the developed HPLC technique was assessed using stress testing conditions of hydrolysis, oxidation, thermal, photo‐light, and humidity. The validation study was performed for the limit of detection and limit of quantification, linearity, and recoveries were 0.03%, 0.05%, and 0.1132–2.9920 μg/mL (R2 > 0.999), and 84.09%–109.74%, respectively. The proposed method is highly suitable for the determination of assay, organic impurities, and degradation products of the hydroxyzine. The chemical structure of degradation product 1 (hydroxyzine N‐Oxide) and degradation product 2 (O‐Acetyl hydroxyzine) were identified with the supporting data of LC‐mass spectrometry (LC‐MS) and high‐resolution MS.
Reference34 articles.
1. ICH. Q3A(R2).Impurities in new drug substances. Accessed July 20 2021.https://database.ich.org/sites/default/files/Q3A%28R2%29%20Guideline.pdf
2. ICH. Q3B(R2).Impurities in new drug products. Accessed July 20 2021.https://database.ich.org/sites/default/files/Q3B%28R2%29%20Guideline.pdf
3. ICH. Q3C(R4).Impurities: a guideline for residual solvents.2009.http://www.ich.org/LOB/media/MEDIA5254.pdf
4. Impurity profile of macitentan in tablet dosage form using a stability-indicating high performance liquid chromatography method and forced degradation study
5. Impurity Profiling and a Stability-Indicating UPLC Method Development and Validation for the Estimation of Related Impurities of Halobetasol Propionate in Halobetasol Propionate 0.05% (w/w) Cream
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献