Impact of contact force on the lesion characteristics of very high‐power short‐duration ablation using a QDOT‐MICRO catheter

Author:

Yamaguchi Junji12ORCID,Takigawa Masateru1,Goya Masahiko1ORCID,Martin Claire A.3,Negishi Miho1,Yamamoto Tasuku1,Ikenouchi Takashi1,Goto Kentaro1,Shigeta Takatoshi1ORCID,Kawamura Iwanari1,Nishimura Takuro1,Takamiya Tomomasa1,Tao Susumu1,Miyazaki Shinsuke1,Sasano Tetsuo1ORCID

Affiliation:

1. Department of Cardiovascular Medicine Tokyo Medical and Dental University Hospital Tokyo Japan

2. Department of Clinical and Diagnostic Laboratory Science Tokyo Medical and Dental University Tokyo Japan

3. Department of Cardiology Royal Papworth Hospital Cambridge UK

Abstract

AbstractBackgroundLesion size is reported to become larger as contact force (CF) increases. However, this has not been systematically evaluated in temperature‐guided very high‐power short‐duration (vHPSD) ablation, which was therefore the purpose of this study.MethodsRadiofrequency applications (90 W/4 s, temperature‐control mode) were performed in excised porcine myocardium with four different CFs of 5, 15, 25, and 35 g using QDOT‐MICRO™ catheter. Ten lesions for each combination of settings were created, and lesion metrics and steam‐pops were compared.ResultsA total of 320 lesions were analyzed. Lesion depth, surface area, and volume were smallest for CF of 5 g than for 15, 25, and 35 g (depth: 2.7 mm vs. 2.9 mm, 3.0 mm, 3.15 mm, p < .01; surface area: 38.4 mm2 vs. 41.8 mm2, 43.3 mm2, 41.5 mm2, p < .05; volume: 98.2 mm3 vs. 133.3 mm3, 129.4 mm3, 126.8 mm3, p < .01 for all pairs of groups compared to CF = 5 g). However, no significant differences were observed between CFs of 15–35 g. Average power was highest for CF of 5 g, followed by 15, 25, and 35 g (83.2 W vs. 82.1 W vs. 77.1 W vs. 66.1 W, p < .01 for all pairs), reflecting the higher incidence of temperature‐guided power titration with greater CFs (5 g:8.8% vs. 15 g:52.5% vs. 25 g:77.5% vs. 35 g:91.2%, p < .01 for all pairs except for 25 g vs. 35 g). The incidence of steam‐pops did not significantly differ between four groups (5 g:3.8% vs. 15 g:10% vs. 25 g:6.2% vs. 35 g:2.5%, not significant for all pairs).ConclusionsFor vHPSD ablation, lesion size does not become large once the CF reaches 15 g, and the risk of steam‐pops may be mitigated through power titration even in high CFs.

Funder

Japan Society for the Promotion of Science

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3