Investigation of a 3D dosimetry system utilizing radio‐chromic gel and telecentric optical‐CT readout

Author:

Hoopingarner Scott12,Oldham Mark2,Adamson Justus2,Lakrad Kawtar2

Affiliation:

1. UC Davis Comprehensive Cancer Center Sacramento California USA

2. Duke University Medical Center Durham North Carolina USA

Abstract

AbstractBackgroundSophisticated modern radiation therapy treatments require comprehensive validation in 3D.PurposeInvestigation and characterization of a novel 3D dosimetry system consisting of ClearView radiochromic gel dosimeters (commercially available from Modus Inc) and an in‐house telecentric optical CT scanner DLOS (the Duke Large Field of View Optical‐CT Scanner).MethodsSpectrophotometry measurements were made on small volumes of ClearView gel irradiated with 6X photon doses up to 40 Gy to determine linearity and temporal stability of dose response. Clinical evaluation of Clearview/DLOS system was conducted in two phases. Phase one involved simple photon and electron benchmark irradiations, delivered to 15 and 10 cm diameter dosimeters, at various energies and doses. Phase 2 investigated application to the verification of two single isocenter multi‐target (SIMT) stereotactic radiosurgery (SRS) deliveries. These were patient treatments for two and five brain lesions, respectively, and delivered to 15 cm diameter dosimeters. SIMT treatments were delivered by Varian TrueBeam 6X with doses of 40 Gy. For dose read‐out, dosimeters were optically scanned in the DLOS both pre‐ and post‐ irradiation (within 24 h). 3D reconstructions (1 mm3 resolution) of the change in linear‐optical‐ attenuation (proportional to dose) was obtained using in‐house software and 3D Slicer. Measured and predicted (Eclipse TPS) doses were compared through percent depth‐dose (PDD), cross plane and in‐plane profiles, and relative 3D gamma analysis (performed at a range of 7%/4 mm down to 2%/2 mm). Regions of known artifacts were excluded from analysis (jar base, neck, and wall). The SIMT SRS deliveries were additionally compared to SciMoca, an independent Monte Carlo second check software.ResultsLinearity of dose response was confirmed with R2 ≥ 0.9986 at both 520 and 630 nm wavelengths and at three post‐irradiation time points: 21 h, 6 and 10 days. Dose profiles of all benchmark irradiations, in both 15 and 10 cm dosimeters, show good agreement in useable areas of the gel compared to Eclipse dose calculations, with root mean square errors (RMSE) ≤ 0.0054, and R2 ≥ 0.9808. Gamma pass rates for the 15 cm dosimeter benchmark irradiations were ≥ 94% at 2%/2 mm (central axis), ≥ 90% at 3%/3 mm (left lateral), ≥ 90% at 2%/2 mm (electron), and ≥ 94% at 3%/2 mm (stacking field). Similar high passing rates were observed for benchmark irradiations to the smaller 10 cm diameter dosimeters. Very high Gamma pass rates were found for SIMT SRS deliveries, with 99.82% and 97.80% at 3%/2 mm, for the two and five target plans, respectively.ConclusionThis work presents the first investigation of ClearView dosimeters in combination with a telecentric optical‐CT scanner (DLOS). Simple benchmark irradiations demonstrate ClearView/DLOS can accurately recreate and measure relative 3D dose within non‐artifact regions (i.e., > 1 cm away from walls). Application to SIMT SRS deliveries demonstrated the viability of the system as a means for comprehensive 3D verification of complex treatment deliveries as well as confirming the treatment planning system dose distribution. The results indicate that DLOS/ClearView system is a highly effective 3D verification tool for SIMT irradiations and can be applied with 3%/2 mm gamma criteria where passing rates of > 95% are to be expected.

Publisher

Wiley

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3