Open‐source myocardial T1 mapping with simultaneous multi‐slice acceleration: Combining an auto‐calibrated blipped‐bSSFP readout with VERSE‐MB pulses

Author:

Gaspar Andreia S.1ORCID,Silva Nuno A.2,Price Anthony N.3ORCID,Ferreira António M.45,Nunes Rita G.1ORCID

Affiliation:

1. Instituto de Sistemas e Robótica – Lisboa and Departamento de Bioengenharia, Instituto Superior Técnico, Universidade de Lisboa Lisbon Portugal

2. Hospital da Luz Learning Health, Luz Saúde Lisbon Portugal

3. Medical Physics, Guy's & St Thomas' NHS Foundation Trust London UK

4. Serviço de Cardiologia, Hospital de Santa Cruz, Centro Hospitalar Lisboa Ocidental Lisbon Portugal

5. Unidade de Imagiologia Cardíaca Avançada, Hospital da Luz Lisbon Portugal

Abstract

PurposeEnabling fast and accessible myocardial T1 mapping is crucial for extending its clinical application. We introduce Open‐MOLLI‐SMS combining simultaneous multi‐slice (SMS) with auto‐calibration and variable‐rate selective excitation (VERSE)‐multiband pulses to obtain all slices in a fast single‐shot T1 mapping sequence.MethodsOpen‐MOLLI‐SMS was developed by integrating SMS with the open‐source method Open‐MOLLI previously implemented in Pulseq. Three methods were integrated for Open‐MOLLI‐SMS: (1) auto‐calibration blip patterns to ensure consistency between the data and coil information; (2) a blipped‐balanced SSFP (bSSFP) readout to induce controlled aliasing in parallel imaging shifts without disturbing the bSSFP frequency response; and (3) a VERSE‐multiband pulse for minimizing the achievable TR and the specific absortion rate (SAR) impact of SMS. Two (SMS2) or three (SMS3) slices were excited simultaneously and encoded with an in‐plane acceleration factor of 2. Experiments were performed in the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology phantom and five healthy volunteers.ResultsPhantom results show accurate T1 estimates for reference values between 400 to 2200 ms. Artifacts were visible for Open‐MOLLI‐SMS3 but not replicated in vivo. In vivo Open‐MOLLI‐SMS (T1SMS2 = 993 ± 10 ms; T1SMS3 = 1031 ± 17 ms) provided similar values to mean T1 single‐band Open‐MOLLI estimates (T1Open‐MOLLI = 1005 ± 47 ms). Open‐MOLLI‐SMS2 provided the closest estimates to the reference.ConclusionThis proof‐of‐principle implementation study demonstrates the feasibility of speeding up T1‐mapping acquisitions and increasing coverage by combining auto‐calibration strategies with a blipped‐bSFFP readout and VERSE multiband RF excitation pulses. The proposed methodology was built on the Open‐MOLLI mapping sequence, which provides a fast means for prototyping and enables open‐source sharing of the method.

Funder

Fundação para a Ciência e a Tecnologia

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3